Tactile Sensor-Based Body Center of Pressure Estimation System Using Supervised Deep Learning Models

The center of pressure (CoP) is a key biomechanical indicator for assessing balance and fall risk; however, force plates, the gold standard for CoP measurement, are costly and impractical for widespread use. Low-cost alternatives such as inertial units or pressure sensors are limited by drift, sparse sensor coverage, and directional performance imbalances, with previous supervised learning approaches reporting ML-AP NRMSE differences of 3.2-4.7% using 1D time-series models on sparse sensor arrays. Therefore, we propose a tactile sensor-based CoP estimation system using deep learning models that can extract 2D spatial features from each pressure distribution image with CNN/ResNet encoders followed by a Bi-LSTM for temporal patterns. Using data from 23 healthy adults performing four balance protocols, we compared ResNet-Bi-LSTM and CNN-Bi-LSTM with baseline CNN-LSTM and Bi-LSTM models used in previous studies. Model performance was validated using leave-one-out cross-validation (LOOCV) and evaluated with RMSE, NRMSE, and R<sup>2</sup>. The ResNet-Bi-LSTM with angular features achieved the best performance, with RMSE values of 18.63 ± 4.57 mm in the mediolateral (ML) direction and 17.65 ± 3.48 mm in the anteroposterior (AP) direction, while reducing the ML/AP NRMSE difference to 1.3% compared to 3.2-4.7% in previous studies. Under dynamic protocols, ResNet-Bi-LSTM maintained the lowest RMSE across models. These findings suggest that tactile sensor-based systems may provide a cost-effective alternative to force plates and hold potential for applications in gait analysis and real-time balance monitoring. Future work will validate clinical applicability in patient populations and explore real-time implementation.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-02
DOI
https://doi.org/10.3390/s26010286
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tactile Sensor-Based Body Center of Pressure Estimation System Using Supervised Deep Learning Models

Y. K. Choi, Young Jin Park, Hosu Lee, Jaehyeon Baik et al.
Sensors
Balance, Gait, and Falls Prevention
article

Tactile Sensor-Based Body Center of Pressure Estimation System Using Supervised Deep Learning Models

Y. K. Choi, Young Jin Park, Hosu Lee, Jaehyeon Baik, Kyung-Joong Kim
article en

Abstract

The center of pressure (CoP) is a key biomechanical indicator for assessing balance and fall risk; however, force plates, the gold standard for CoP measurement, are costly and impractical for widespread use. Low-cost alternatives such as inertial units or pressure sensors are limited by drift, sparse sensor coverage, and directional performance imbalances, with previous supervised learning approaches reporting ML-AP NRMSE differences of 3.2-4.7% using 1D time-series models on sparse sensor arrays. Therefore, we propose a tactile sensor-based CoP estimation system using deep learning models that can extract 2D spatial features from each pressure distribution image with CNN/ResNet encoders followed by a Bi-LSTM for temporal patterns. Using data from 23 healthy adults performing four balance protocols, we compared ResNet-Bi-LSTM and CNN-Bi-LSTM with baseline CNN-LSTM and Bi-LSTM models used in previous studies. Model performance was validated using leave-one-out cross-validation (LOOCV) and evaluated with RMSE, NRMSE, and R<sup>2</sup>. The ResNet-Bi-LSTM with angular features achieved the best performance, with RMSE values of 18.63 ± 4.57 mm in the mediolateral (ML) direction and 17.65 ± 3.48 mm in the anteroposterior (AP) direction, while reducing the ML/AP NRMSE difference to 1.3% compared to 3.2-4.7% in previous studies. Under dynamic protocols, ResNet-Bi-LSTM maintained the lowest RMSE across models. These findings suggest that tactile sensor-based systems may provide a cost-effective alternative to force plates and hold potential for applications in gait analysis and real-time balance monitoring. Future work will validate clinical applicability in patient populations and explore real-time implementation.

SensorsVol. 26(1)
Gyeongnam National University of Science and Technology (KR), Gyeongsang National University (KR), University of Washington (US), Gwangju Institute of Science and Technology (KR)
National Research Foundation, Gyeongsang National University, National Research Foundation of Korea, Ministry of Education, India, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 99%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.