The Effect of Orthokeratology Lens Decentration on Ocular and Biomechanical Measurements

Xiuli Hu,1,* Chenpei Zhao,2– 4,* Weicong Lu,5 Yuyin Tian,2– 4 Dongdong Jiang,2– 4 Wenzhi Ding,2– 4 Lin Leng2– 4 1Experimental Teaching of Clinical Skills Center, Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China; 2Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, People’s Republic of China; 3Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, People’s Republic of China; 4School of Ophthalmology, Shandong First Medical University, Qingdao, Shandong, People’s Republic of China; 5School of Optometry and Ophthalmology, The Eye Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China*These authors contributed equally to this workCorrespondence: Lin Leng, Eye Institute of Shandong First Medical University, No. 5, Yanerdao Road, Qingdao, Shandong, 266071, People’s Republic of China, Tel +86-0532-87610198, Email [email protected]: To investigate the effects of orthokeratology (ortho-K) lens decentration on ocular and biomechanical parameters and analyze the correlation of these parameters with decentration distance.Methods: Thirty eyes of 30 myopic adult subjects, mean age 28.2 years who had worn ortho-K lens for two hours were recruited for this prospective study. Under both the central and eccentric lens fitting conditions, the subjects underwent two rounds of assessments with a week-long interval. The ocular parameters were measured by an IOL Master, whereas the biomechanical parameters were measured by a Corves ST. Differences between measurements were evaluated by one-way ANOVA and a post hoc test. Repeatability was analyzed based on within-subject standard deviation (Sw), repeatability coefficient (RC), intraclass correlation coefficient (ICC), and correlation of variation (CoV). Pearson correlation analysis was employed for correlation analysis.Results: The ocular parameters showed no significant differences, whereas among the biomechanical parameters, the biomechanical corrected intraocular pressure (bIOP) (95% CI 15.8– 16.7 mmHg, 14.7– 15.6 mmHg, 14.5– 15.5 mmHg for baseline, central and eccentric group) and stiffness parameter at first applanation (SPA1) (95% CI 111.7– 122.4, 102.3– 113.0, 103.9– 115.1 for baseline, central and eccentric group) showed significant changes after ortho-K. In all groups, the ocular parameters showed good repeatability with ICC values greater than 0.95 and CoV values lower than 1.3%. By contrast, the biomechanical parameters showed poor repeatability with low ICC values (ie, below 0.7) for the length of flattened cornea at the first and second applanations (A1L and A2L, respectively) and for velocity of corneal apex at the second applanation (A2V) in the baseline group; for A1L, A2L, and bIOP in the central group; and for A1L and A2V in the eccentric group. The correlation analysis showed the positive relationship in A2L between central and eccentric groups.Conclusion: Ortho-K lens decentration did not influence the ocular parameters. However, the biomechanical parameters, the bIOP and SPA1 related to corneal thickness changed after ortho-K.Keywords: orthokeratology, decentration, biomechanical parameters, axial length

Authors

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-12-01
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Orthokeratology Lens Decentration on Ocular and Biomechanical Measurements

Ding S-W, Tian Y, Lu W, Zhao C et al.
SHILAP Revista de lepidopterología
Ophthalmology and Visual Impairment Studies
article

The Effect of Orthokeratology Lens Decentration on Ocular and Biomechanical Measurements

Ding S-W, Tian Y, Lu W, Zhao C, Leng L, Jiang D, Hu X
article en

Abstract

Xiuli Hu,1,* Chenpei Zhao,2– 4,* Weicong Lu,5 Yuyin Tian,2– 4 Dongdong Jiang,2– 4 Wenzhi Ding,2– 4 Lin Leng2– 4 1Experimental Teaching of Clinical Skills Center, Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China; 2Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, People’s Republic of China; 3Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, People’s Republic of China; 4School of Ophthalmology, Shandong First Medical University, Qingdao, Shandong, People’s Republic of China; 5School of Optometry and Ophthalmology, The Eye Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China*These authors contributed equally to this workCorrespondence: Lin Leng, Eye Institute of Shandong First Medical University, No. 5, Yanerdao Road, Qingdao, Shandong, 266071, People’s Republic of China, Tel +86-0532-87610198, Email [email protected]: To investigate the effects of orthokeratology (ortho-K) lens decentration on ocular and biomechanical parameters and analyze the correlation of these parameters with decentration distance.Methods: Thirty eyes of 30 myopic adult subjects, mean age 28.2 years who had worn ortho-K lens for two hours were recruited for this prospective study. Under both the central and eccentric lens fitting conditions, the subjects underwent two rounds of assessments with a week-long interval. The ocular parameters were measured by an IOL Master, whereas the biomechanical parameters were measured by a Corves ST. Differences between measurements were evaluated by one-way ANOVA and a post hoc test. Repeatability was analyzed based on within-subject standard deviation (Sw), repeatability coefficient (RC), intraclass correlation coefficient (ICC), and correlation of variation (CoV). Pearson correlation analysis was employed for correlation analysis.Results: The ocular parameters showed no significant differences, whereas among the biomechanical parameters, the biomechanical corrected intraocular pressure (bIOP) (95% CI 15.8– 16.7 mmHg, 14.7– 15.6 mmHg, 14.5– 15.5 mmHg for baseline, central and eccentric group) and stiffness parameter at first applanation (SPA1) (95% CI 111.7– 122.4, 102.3– 113.0, 103.9– 115.1 for baseline, central and eccentric group) showed significant changes after ortho-K. In all groups, the ocular parameters showed good repeatability with ICC values greater than 0.95 and CoV values lower than 1.3%. By contrast, the biomechanical parameters showed poor repeatability with low ICC values (ie, below 0.7) for the length of flattened cornea at the first and second applanations (A1L and A2L, respectively) and for velocity of corneal apex at the second applanation (A2V) in the baseline group; for A1L, A2L, and bIOP in the central group; and for A1L and A2V in the eccentric group. The correlation analysis showed the positive relationship in A2L between central and eccentric groups.Conclusion: Ortho-K lens decentration did not influence the ocular parameters. However, the biomechanical parameters, the bIOP and SPA1 related to corneal thickness changed after ortho-K.Keywords: orthokeratology, decentration, biomechanical parameters, axial length

SHILAP Revista de lepidopterología
American Academy of Optometry (US)
Quality Education
Openalex Percentile: Top 28%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.