PLUME-OCT: A quality control tool to enhance statistical power in the analysis of biomarkers from 3D biomedical datasets of OCT images

High-dimensional imaging data are central to biomedical research, enabling extraction of quantitative biomarkers for disease modeling and association studies. While quality control (QC) often targets individual 2D slices, many applications rely on the integrity of full 3D volumes. Optical coherence tomography (OCT), used here as a representative modality, illustrates the need for automated QC methods assessing volumetric coherence to support reliable biomarker extraction. We developed Phase-Level Unified Metric Evaluation (PLUME-OCT), a preprocessing tool that quantifies inter-slice misalignments in 3D biomedical image volumes using a Discrete Fourier Transform-based approach. The method was validated against 73,920 pairwise comparisons annotated by four human graders across 40 OCT volumes from the OphthalmoLaus cohort. As a large-scale case study, PLUME-OCT was applied for QC of 88,247 OCT scans from the UK Biobank prior to 3D biomarker extraction and genome-wide association analysis. PLUME-OCT effectively ranked OCT scans by quality, detecting misalignments between OCT B-scans in agreement with human annotators. In large datasets, its use enhanced the detection of statistically significant signals in 3D retinal biomarkers analysis, increasing significant genetic associations by 21.1 % (p = 1.6 × 10<sup>-7</sup>) and heritability estimates by 19.1 % (p = 5.0 × 10<sup>-12</sup>) across 30 genome-wide association studies. PLUME-OCT is an open-source, lightweight, and scalable QA tool that enhances statistical power in 3D biomarkers analysis from biomedical imaging datasets. Although demonstrated on retinal OCT, the method applies broadly to other volumetric imaging modalities and can be seamlessly integrated into biomedical informatics workflows for high-quality, large-scale data preprocessing.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2025-12-31
DOI
https://doi.org/10.1016/j.compbiomed.2025.111420
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PLUME-OCT: A quality control tool to enhance statistical power in the analysis of biomarkers from 3D biomedical datasets of OCT images

Sofía Ortín Vela, Grégoire Molas, Flavie Torrecillos, Ilenia Meloni et al.
Computers in Biology and Medicine
Optical Coherence Tomography Applications
article

PLUME-OCT: A quality control tool to enhance statistical power in the analysis of biomarkers from 3D biomedical datasets of OCT images

Sofía Ortín Vela, Grégoire Molas, Flavie Torrecillos, Ilenia Meloni, Ciara Bergin, Alexandre Bouillon, Mattia Tomasoni, David M. Presby, Dennis Bontempi, Sandro De Zanet, Victor Amiot, Alicia Milloz, Laurent Gurtler, James Bardet, Mathieu Charbonnier, Sven Bergmann, Yves Paychère, Reinier Schlingemann
article en

Abstract

High-dimensional imaging data are central to biomedical research, enabling extraction of quantitative biomarkers for disease modeling and association studies. While quality control (QC) often targets individual 2D slices, many applications rely on the integrity of full 3D volumes. Optical coherence tomography (OCT), used here as a representative modality, illustrates the need for automated QC methods assessing volumetric coherence to support reliable biomarker extraction. We developed Phase-Level Unified Metric Evaluation (PLUME-OCT), a preprocessing tool that quantifies inter-slice misalignments in 3D biomedical image volumes using a Discrete Fourier Transform-based approach. The method was validated against 73,920 pairwise comparisons annotated by four human graders across 40 OCT volumes from the OphthalmoLaus cohort. As a large-scale case study, PLUME-OCT was applied for QC of 88,247 OCT scans from the UK Biobank prior to 3D biomarker extraction and genome-wide association analysis. PLUME-OCT effectively ranked OCT scans by quality, detecting misalignments between OCT B-scans in agreement with human annotators. In large datasets, its use enhanced the detection of statistically significant signals in 3D retinal biomarkers analysis, increasing significant genetic associations by 21.1 % (p = 1.6 × 10<sup>-7</sup>) and heritability estimates by 19.1 % (p = 5.0 × 10<sup>-12</sup>) across 30 genome-wide association studies. PLUME-OCT is an open-source, lightweight, and scalable QA tool that enhances statistical power in 3D biomarkers analysis from biomedical imaging datasets. Although demonstrated on retinal OCT, the method applies broadly to other volumetric imaging modalities and can be seamlessly integrated into biomedical informatics workflows for high-quality, large-scale data preprocessing.

Computers in Biology and MedicineVol. 201
SIB Swiss Institute of Bioinformatics (CH), Fondation Asile des Aveugles (CH), University of Lausanne (CH)
Openalex Percentile: Top 41%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.