A novel agar-based phantom for quality control of medical ultrasound devices

Abstract Introduction Regular quality control and verification of medical ultrasound systems are essential for maintaining high diagnostic accuracy. However, the high cost of commercial phantoms often limits their use, particularly in smaller healthcare facilities. This study aimed to develop a low-cost agar-based phantom and evaluate its suitability for ultra-sound quality control. Material and methods The phantom was constructed using a plexiglass container filled with a 30 g/L agar solution. Test structures of different sizes were incorporated using nylon threads, small wooden pieces, and agar mixed with graphite. Measurements were performed with Voluson 730 Expert and GE Healthcare LOGIQ α 100 systems. Results Quality control tests included assessments of image uniformity, contrast resolution, spatial resolution, dead zone, maximum penetration depth, and geometric accuracy. The presence of targets of varying sizes enabled evaluations consistent with international quality assurance guidelines. During testing, several image artifacts and minor malfunctions were observed, likely resulting from trapped air bubbles or transducer imperfections, which could influence image interpretation. Nevertheless, the results indicate that the developed phantom performs reliably for key ultrasound quality control procedures. Conclusions Its simple design, inexpensive materials, and adaptability make it particularly suitable for routine checks and training applications. Furthermore, its easy reproducibility allows customization for different clinical needs and equipment types. Overall, this study demonstrates that an agar-based phantom can serve as an effective, low-cost alternative to commercial models, supporting systematic quality control in ultrasound imaging. Such accessible solutions may help standardize testing procedures, enhance diagnostic consistency, and ultimately improve patient safety.

Authors

Institutions

Publication Details

Journal
Polish Journal of Medical Physics And Engineering
Published
2025-12-01
DOI
https://doi.org/10.2478/pjmpe-2025-0038
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel agar-based phantom for quality control of medical ultrasound devices

Katarzyna Matusiak, Weronika Banowska
Polish Journal of Medical Physics And Engineering
Ultrasound Imaging and Elastography
article

A novel agar-based phantom for quality control of medical ultrasound devices

Katarzyna Matusiak, Weronika Banowska
article en

Abstract

Abstract Introduction Regular quality control and verification of medical ultrasound systems are essential for maintaining high diagnostic accuracy. However, the high cost of commercial phantoms often limits their use, particularly in smaller healthcare facilities. This study aimed to develop a low-cost agar-based phantom and evaluate its suitability for ultra-sound quality control. Material and methods The phantom was constructed using a plexiglass container filled with a 30 g/L agar solution. Test structures of different sizes were incorporated using nylon threads, small wooden pieces, and agar mixed with graphite. Measurements were performed with Voluson 730 Expert and GE Healthcare LOGIQ α 100 systems. Results Quality control tests included assessments of image uniformity, contrast resolution, spatial resolution, dead zone, maximum penetration depth, and geometric accuracy. The presence of targets of varying sizes enabled evaluations consistent with international quality assurance guidelines. During testing, several image artifacts and minor malfunctions were observed, likely resulting from trapped air bubbles or transducer imperfections, which could influence image interpretation. Nevertheless, the results indicate that the developed phantom performs reliably for key ultrasound quality control procedures. Conclusions Its simple design, inexpensive materials, and adaptability make it particularly suitable for routine checks and training applications. Furthermore, its easy reproducibility allows customization for different clinical needs and equipment types. Overall, this study demonstrates that an agar-based phantom can serve as an effective, low-cost alternative to commercial models, supporting systematic quality control in ultrasound imaging. Such accessible solutions may help standardize testing procedures, enhance diagnostic consistency, and ultimately improve patient safety.

Polish Journal of Medical Physics And EngineeringVol. 31(4)
Jagiellonian University (PL), AGH University of Krakow (PL)
Partnerships for the goals
Openalex Percentile: Top 29%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.