Optimization of distributed generation placement in distribution network based on queen honey bee migration algorithm

In this research, an optimal distributed generation (DG) placement method for radial distribution systems based on queen honey bee migration (QHBM) and backward forward sweep (BFS) is presented. The suggested approach makes it possible to evaluate DG placement options in terms of branch currents, voltage profiles, and active power losses in a physically consistent manner. DG units are characterized as photovoltaic-based sources operating at unity power factor using an explicit net load formulation at the bus level, ensuring a clear interplay between DG injection and current-based load flows. Throughout the optimization process, a constraint-aware migration technique is employed to explicitly impose voltage limitations with the goal of minimizing overall active power losses while maintaining bus voltage magnitudes within allowable bounds. The proposed method was tested on an IEEE 69-bus radial distribution system to evaluate its performance. The results show that the placement of three DG units with a total installed capacity of approximately 2600 kW at buses 61, 64, and 17 produces a significant improvement in network operation. Under this arrangement, active power losses drop markedly from 224.4419 kW in the base condition to 72.7840 kW, corresponding to a reduction of 67.6 %. At the same time, the lowest bus voltage rises from 0.9104 p.u. to 0.9931 p.u., while voltage levels across the network consistently remain within the allowable range of 0.95–1.05 p.u. The study's findings suggest that QHBM-BFS can be used as a trustworthy and useful method for figuring out where DG should be placed in radial distribution systems.

Authors

Institutions

Publication Details

Journal
Mechatronics Electrical Power and Vehicular Technology
Published
2025-12-30
DOI
https://doi.org/10.55981/j.mev.2025.856
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of distributed generation placement in distribution network based on queen honey bee migration algorithm

Norzanah Rosmin, A Aripriharta, S Sujito, Gwo Jiun Horng et al.
Mechatronics Electrical Power and Vehicular Technology
Optimal Power Flow Distribution
article

Optimization of distributed generation placement in distribution network based on queen honey bee migration algorithm

Norzanah Rosmin, A Aripriharta, S Sujito, Gwo Jiun Horng, S. B. S. Omar, Muhammad Cahyo Bagaskoro, Alif Dhurrotul Fachriyyah, Muchamad Wahyu Prasetyo
article en

Abstract

In this research, an optimal distributed generation (DG) placement method for radial distribution systems based on queen honey bee migration (QHBM) and backward forward sweep (BFS) is presented. The suggested approach makes it possible to evaluate DG placement options in terms of branch currents, voltage profiles, and active power losses in a physically consistent manner. DG units are characterized as photovoltaic-based sources operating at unity power factor using an explicit net load formulation at the bus level, ensuring a clear interplay between DG injection and current-based load flows. Throughout the optimization process, a constraint-aware migration technique is employed to explicitly impose voltage limitations with the goal of minimizing overall active power losses while maintaining bus voltage magnitudes within allowable bounds. The proposed method was tested on an IEEE 69-bus radial distribution system to evaluate its performance. The results show that the placement of three DG units with a total installed capacity of approximately 2600 kW at buses 61, 64, and 17 produces a significant improvement in network operation. Under this arrangement, active power losses drop markedly from 224.4419 kW in the base condition to 72.7840 kW, corresponding to a reduction of 67.6 %. At the same time, the lowest bus voltage rises from 0.9104 p.u. to 0.9931 p.u., while voltage levels across the network consistently remain within the allowable range of 0.95–1.05 p.u. The study's findings suggest that QHBM-BFS can be used as a trustworthy and useful method for figuring out where DG should be placed in radial distribution systems.

Mechatronics Electrical Power and Vehicular TechnologyVol. 16(2)
State University of Malang (ID), Universiti Teknologi MARA (MY), Southern Taiwan University of Science and Technology (TW)
Reduced inequalities
Openalex Percentile: Top 40%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.