Optimization of Isolated Microgrid Sizing Considering the Trade-Off Between Costs and Power Supply Reliability

Isolated microgrids with green hydrogen storage offer a promising solution for supplying electricity to remote communities where conventional grid expansion is infeasible. Designing such systems requires balancing two conflicting objectives: minimizing installation and operation costs while maximizing supply reliability. This paper proposes a multi-objective optimization methodology, based on the Non-dominated Sorting Genetic Algorithm II, to determine the optimal sizing of multiple microgrid components. This sizing explicitly addresses both the power capacities (kW) (for photovoltaic panels, wind turbines, electrolyzers, and fuel cells) and the energy storage capacities (kWh and kg) (for batteries and hydrogen tanks, respectively), aiming to generate Pareto-optimal solutions that explore this trade-off. The proposed method evaluates the trade-off by minimizing two objectives: the Net Present Value, which includes investment, replacement, and maintenance costs, and the total expected interruption hours, derived from an hourly energy balance analysis. The methodology’s effectiveness is validated using four distinct case studies. Three of these are based on real locations with specific load profiles and climate data. To test the method’s robustness, a fourth case study uses a fictitious load profile, designed with pronounced seasonal variations and a clear distinction between weekday and weekend consumption. Our results demonstrate the method’s ability to identify efficient hybrid renewable topologies combining photovoltaic and/or wind generation, batteries, and hydrogen systems (electrolyzer, storage tank, and fuel cell). The obtained cost–reliability curves provide practical decision-support tools for system planners.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-12-30
DOI
https://doi.org/10.3390/en19010195
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Isolated Microgrid Sizing Considering the Trade-Off Between Costs and Power Supply Reliability

J.B. Vieira, Welisson Barbosa Costa, Igor Luiz Dal Forno, Caio Rodrigues Barroso et al.
Energies
Hybrid Renewable Energy Systems
article

Optimization of Isolated Microgrid Sizing Considering the Trade-Off Between Costs and Power Supply Reliability

J.B. Vieira, Welisson Barbosa Costa, Igor Luiz Dal Forno, Caio Rodrigues Barroso, Caison Rodrigues Ramos, GUSTAVO BARROS MARCHESAN, Rodrigo Modesto Gadelha, Tiago Pitol Mroginski, Mariana Resener, Eduardo de Campos, André P. Leão, Vitor Batista, Ghendy Cardoso, Olinto Araújo
article en

Abstract

Isolated microgrids with green hydrogen storage offer a promising solution for supplying electricity to remote communities where conventional grid expansion is infeasible. Designing such systems requires balancing two conflicting objectives: minimizing installation and operation costs while maximizing supply reliability. This paper proposes a multi-objective optimization methodology, based on the Non-dominated Sorting Genetic Algorithm II, to determine the optimal sizing of multiple microgrid components. This sizing explicitly addresses both the power capacities (kW) (for photovoltaic panels, wind turbines, electrolyzers, and fuel cells) and the energy storage capacities (kWh and kg) (for batteries and hydrogen tanks, respectively), aiming to generate Pareto-optimal solutions that explore this trade-off. The proposed method evaluates the trade-off by minimizing two objectives: the Net Present Value, which includes investment, replacement, and maintenance costs, and the total expected interruption hours, derived from an hourly energy balance analysis. The methodology’s effectiveness is validated using four distinct case studies. Three of these are based on real locations with specific load profiles and climate data. To test the method’s robustness, a fourth case study uses a fictitious load profile, designed with pronounced seasonal variations and a clear distinction between weekday and weekend consumption. Our results demonstrate the method’s ability to identify efficient hybrid renewable topologies combining photovoltaic and/or wind generation, batteries, and hydrogen systems (electrolyzer, storage tank, and fuel cell). The obtained cost–reliability curves provide practical decision-support tools for system planners.

EnergiesVol. 19(1)
Universidade de Brasília (BR), Simon Fraser University (CA), Universidade Federal de Santa Maria (BR), Universidade Federal do Pará (BR)
Climate action
Openalex Percentile: Top 43%
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.