Hybrid Sliding Mode Control with Integral Resonant Control for Chattering Reduction in a 3-DOF Lower-Limb Exoskeleton Rehabilitation

Lower-limb exoskeletons have become an effective tool for gait rehabilitation by enabling precise and repetitive joint movements for individuals with motor impairments. Nevertheless, the nonlinear and uncertain nature of human–robot interaction dynamics requires effective control strategies that are both robust and smooth. Conventional sliding mode control (SMC) provides robustness against disturbances but, in effect, is prone to chattering, which can adversely cause mechanical vibrations and reduce user comfort. This paper proposes a novel hybrid sliding mode control integrated with integral resonant control (SMC + IRC), strategy addressing a gap in 3-DOF exoskeleton control where structural resonance and chattering mitigation are simultaneously required while maintaining robustness and trajectory accuracy. The IRC component in this work uses a resonant damping mechanism to filter high-frequency switching elements in the SMC signal, resulting in smoother actuator torques without compromising system stability, robustness or responsiveness. The proposed control framework here is implemented on a lower-limb exoskeleton with hip, knee, and ankle joints and compared to classical SMC and Super-Twisting SMC (STSMC) methods. Upon simulation, results showed that the SMC + IRC approach significantly reduces chattering as well as produces smoother torque profiles while maintaining high tracking precision. Quantitative analyses using RMSE and chattering index metrics prove the superior performance of the proposed controller over the previous ones, establishing it as a practical and effective solution for safe and comfortable rehabilitation motion in real-time exoskeleton systems.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-12-30
DOI
https://doi.org/10.3390/app16010410
Citations
1
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid Sliding Mode Control with Integral Resonant Control for Chattering Reduction in a 3-DOF Lower-Limb Exoskeleton Rehabilitation

Nizar Rokbani, Abdulrahman Alqahtani, Muktar Fatihu Hamza, Auwalu M. Abdullahi
1 citations
Applied Sciences
Prosthetics and Rehabilitation Robotics
0.67
article

Hybrid Sliding Mode Control with Integral Resonant Control for Chattering Reduction in a 3-DOF Lower-Limb Exoskeleton Rehabilitation

Nizar Rokbani, Abdulrahman Alqahtani, Muktar Fatihu Hamza, Auwalu M. Abdullahi
article en
1 citations

Abstract

Lower-limb exoskeletons have become an effective tool for gait rehabilitation by enabling precise and repetitive joint movements for individuals with motor impairments. Nevertheless, the nonlinear and uncertain nature of human–robot interaction dynamics requires effective control strategies that are both robust and smooth. Conventional sliding mode control (SMC) provides robustness against disturbances but, in effect, is prone to chattering, which can adversely cause mechanical vibrations and reduce user comfort. This paper proposes a novel hybrid sliding mode control integrated with integral resonant control (SMC + IRC), strategy addressing a gap in 3-DOF exoskeleton control where structural resonance and chattering mitigation are simultaneously required while maintaining robustness and trajectory accuracy. The IRC component in this work uses a resonant damping mechanism to filter high-frequency switching elements in the SMC signal, resulting in smoother actuator torques without compromising system stability, robustness or responsiveness. The proposed control framework here is implemented on a lower-limb exoskeleton with hip, knee, and ankle joints and compared to classical SMC and Super-Twisting SMC (STSMC) methods. Upon simulation, results showed that the SMC + IRC approach significantly reduces chattering as well as produces smoother torque profiles while maintaining high tracking precision. Quantitative analyses using RMSE and chattering index metrics prove the superior performance of the proposed controller over the previous ones, establishing it as a practical and effective solution for safe and comfortable rehabilitation motion in real-time exoskeleton systems.

Applied SciencesVol. 16(1)
Prince Sattam Bin Abdulaziz University (SA), Bayero University Kano (NG)
Openalex Percentile: Top 23%
Prosthetics and Rehabilitation Robotics
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.