Structural integrity and life of hip implants: review of case studies

Hip implants are nowadays typically high-quality and reliable components which rarely fail. Nevertheless, they still sometimes do, due to static, impact or amplitude loading, under hostile environment such as our bodies. Therefore, we still have to analyse factors that may affect both hip implant integrity and life, such as body weight, implant geometry and material. In this paper, a review of recent investigation of hip implant fracture and fatigue behaviour is presented with focus on the effects of body weight, implant geometry and material. It is shown that body weight plays an important role, especially for fatigue life, since the relation between remaining life and stress (proportional to weight) is exponential (typically m = 3 in Paris equation). Regarding implant geometry, it is demonstrated that the main issue is stress analysis. In the case of modular (full cross-section) implants, stress state is more favourable than in the case of implant with holes for fine adjustment according to patient bone configuration. It is also shown that stress level in this case can be surprisingly high, especially with younger, active patients. Finally, the interaction between influencing factors should be taken into account, being a relatively simple task when numerical methods are used.

Authors

Publication Details

Journal
Integritet i vek konstrukcija
Published
2025-12-30
DOI
https://doi.org/10.69644/ivk-2025-03-0509
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural integrity and life of hip implants: review of case studies

Aleksandar Sedmak, Katarina Čolić, Simon A. Sedmak
Integritet i vek konstrukcija
Orthopaedic implants and arthroplasty
article

Structural integrity and life of hip implants: review of case studies

Aleksandar Sedmak, Katarina Čolić, Simon A. Sedmak
article en

Abstract

Hip implants are nowadays typically high-quality and reliable components which rarely fail. Nevertheless, they still sometimes do, due to static, impact or amplitude loading, under hostile environment such as our bodies. Therefore, we still have to analyse factors that may affect both hip implant integrity and life, such as body weight, implant geometry and material. In this paper, a review of recent investigation of hip implant fracture and fatigue behaviour is presented with focus on the effects of body weight, implant geometry and material. It is shown that body weight plays an important role, especially for fatigue life, since the relation between remaining life and stress (proportional to weight) is exponential (typically m = 3 in Paris equation). Regarding implant geometry, it is demonstrated that the main issue is stress analysis. In the case of modular (full cross-section) implants, stress state is more favourable than in the case of implant with holes for fine adjustment according to patient bone configuration. It is also shown that stress level in this case can be surprisingly high, especially with younger, active patients. Finally, the interaction between influencing factors should be taken into account, being a relatively simple task when numerical methods are used.

Integritet i vek konstrukcijaVol. 25(3)
Openalex Percentile: Top 25%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.