Half-segmental Diaphyseal Bone Defect Model in Rats for Evaluating Bone Substitute Performance in Load-bearing Regions

Accurate preclinical evaluation of bone substitute materials demands models that not only support tissue regeneration but also reflect the mechanical challenges of physiological load-bearing conditions. However, most conventional animal bone defect models fall short in this regard. For example, calvarial defect models, though widely used, are created in non-load-bearing regions. Similarly, drill-hole or partial defects in long bones primarily focus on localized healing, lacking sufficient load transfer to assess mechanical support. This study established a standardized half-segmental diaphyseal bone defect model in the rat femur to assess both the mechanical and biological performance of bone substitute materials in a load-bearing context without the use of fixation devices. Using a high-speed handpiece and a specialized cylindrical dental bur, a semi-cylindrical defect measuring 4 mm in length and 1.5 mm in radius was created in the lateral midshaft of the femur. Two representative materials with distinct properties -- Gelatin methacryloyl (GelMA) hydrogel and 3D-printed polymethyl methacrylate (3DP-PMMA) -- were implanted to validate the model's capacity to differentiate the mechanical properties of materials. Radiographic, histological, and immunofluorescent analyses performed at 4 weeks post-implantation revealed that, due to inadequate mechanical support, GelMA implantation led to malunion with fibrous tissue predominance and limited bone integration. In contrast, 3DP-PMMA facilitated the organization of new bone formation, periosteal continuity, and the recruitment of Piezo type mechanosensitive ion channel component 1-expressing (Piezo1<sup>+</sup>) and leptin receptor-expressing (LepR<sup>+</sup>) cells. This model provides a practical and reproducible platform for assessing the load-bearing capacity, osteoinductivity, and osseointegration potential of biomaterials. It can serve as a valuable tool for screening candidate materials for orthopedic applications, such as long bone reconstruction or fracture repair.

Authors

Institutions

Publication Details

Journal
Journal of Visualized Experiments
Published
2025-12-30
DOI
https://doi.org/10.3791/69211
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Half-segmental Diaphyseal Bone Defect Model in Rats for Evaluating Bone Substitute Performance in Load-bearing Regions

Yitian Wang, Feifei Li, Ling Ye, Yuchuan Luo et al.
Journal of Visualized Experiments
Bone Tissue Engineering Materials
article

Half-segmental Diaphyseal Bone Defect Model in Rats for Evaluating Bone Substitute Performance in Load-bearing Regions

Yitian Wang, Feifei Li, Ling Ye, Yuchuan Luo, Jialu Jin, Yiyun Chen, Shuhan Liu, Jiayi Wu, Peng Yu
article en

Abstract

Accurate preclinical evaluation of bone substitute materials demands models that not only support tissue regeneration but also reflect the mechanical challenges of physiological load-bearing conditions. However, most conventional animal bone defect models fall short in this regard. For example, calvarial defect models, though widely used, are created in non-load-bearing regions. Similarly, drill-hole or partial defects in long bones primarily focus on localized healing, lacking sufficient load transfer to assess mechanical support. This study established a standardized half-segmental diaphyseal bone defect model in the rat femur to assess both the mechanical and biological performance of bone substitute materials in a load-bearing context without the use of fixation devices. Using a high-speed handpiece and a specialized cylindrical dental bur, a semi-cylindrical defect measuring 4 mm in length and 1.5 mm in radius was created in the lateral midshaft of the femur. Two representative materials with distinct properties -- Gelatin methacryloyl (GelMA) hydrogel and 3D-printed polymethyl methacrylate (3DP-PMMA) -- were implanted to validate the model's capacity to differentiate the mechanical properties of materials. Radiographic, histological, and immunofluorescent analyses performed at 4 weeks post-implantation revealed that, due to inadequate mechanical support, GelMA implantation led to malunion with fibrous tissue predominance and limited bone integration. In contrast, 3DP-PMMA facilitated the organization of new bone formation, periosteal continuity, and the recruitment of Piezo type mechanosensitive ion channel component 1-expressing (Piezo1<sup>+</sup>) and leptin receptor-expressing (LepR<sup>+</sup>) cells. This model provides a practical and reproducible platform for assessing the load-bearing capacity, osteoinductivity, and osseointegration potential of biomaterials. It can serve as a valuable tool for screening candidate materials for orthopedic applications, such as long bone reconstruction or fracture repair.

Journal of Visualized Experiments(226)
Sichuan University (CN), Stomatology Hospital (CN), State Key Laboratory of Oral Diseases
Openalex Percentile: Top 41%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.