Identification of Energy Costs in The Gowongan Water Supply System of Perumda Air Minum Tirta Moedal, Semarang, Indonesia

Energy use in water supply systems has drawn increasing attention, especially in areas relying on pumps. This study evaluates the E4 pumps system at the Gowongan Water Supply System (SPAM) by Perumda Air Minum Tirta Moedal Semarang City, conducted in April 2025. Real-time measurements were taken using an ultrasonic flowmeter and a digital power meter. The analysis covered pump efficiency, Specific Energy Consumption (SEC), and electricity usage during peak (WBP) and off-peak (LWBP) hours, based on Ministry of Energy Regulation No. 7/2024. The results showed a pump efficiency of 60.3% and an SEC value of 0.221 kWh/m³. Over 83% of electricity was consumed during off-peak hours, indicating the effectiveness of the Variable Speed Drive (VSD) implementation. The audit also recommends optimizing pump operation schedules and exploring alternative energy sources as strategies to improve operational efficiency.

Authors

Institutions

Publication Details

Journal
Jurnal IPTEK
Published
2025-12-30
DOI
https://doi.org/10.31284/j.iptek.2025.v29i2.7899
Primary Topic
IoT-based Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification of Energy Costs in The Gowongan Water Supply System of Perumda Air Minum Tirta Moedal, Semarang, Indonesia

Ali Masduqi, Suryanto Suryanto, Afriza Cahya Putri
Jurnal IPTEK
IoT-based Control Systems
article

Identification of Energy Costs in The Gowongan Water Supply System of Perumda Air Minum Tirta Moedal, Semarang, Indonesia

Ali Masduqi, Suryanto Suryanto, Afriza Cahya Putri
article en

Abstract

Energy use in water supply systems has drawn increasing attention, especially in areas relying on pumps. This study evaluates the E4 pumps system at the Gowongan Water Supply System (SPAM) by Perumda Air Minum Tirta Moedal Semarang City, conducted in April 2025. Real-time measurements were taken using an ultrasonic flowmeter and a digital power meter. The analysis covered pump efficiency, Specific Energy Consumption (SEC), and electricity usage during peak (WBP) and off-peak (LWBP) hours, based on Ministry of Energy Regulation No. 7/2024. The results showed a pump efficiency of 60.3% and an SEC value of 0.221 kWh/m³. Over 83% of electricity was consumed during off-peak hours, indicating the effectiveness of the Variable Speed Drive (VSD) implementation. The audit also recommends optimizing pump operation schedules and exploring alternative energy sources as strategies to improve operational efficiency.

Jurnal IPTEKVol. 29(2)
Sepuluh Nopember Institute of Technology (ID)
Affordable and clean energy
Openalex Percentile: Top 27%
IoT-based Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.