Towards Wideband Characterization and Modeling of In-Body to On-Body Intrabody Communication Channels

Implantable intrabody communication (IBC) is a method that enables low-power, high-security communication between implanted in-body devices that could track biomedical signals and an on-body receiver by using the human body as a communication medium. As the human body consists of various tissues that each have different conductivity, this paper explores the effects of the conductivity of the communication medium on the channel gain over a wide frequency range from 10 MHz up to 300 MHz through the measurements and two models: an electrical circuit model and a FEM simulation model. Measurements are conducted using a liquid phantom with varying conductivity values from 0 S/m up to 1 S/m, covering most human tissues in the frequency range of interest. The circuit and FEM models are designed to mimic the measurement setup in order to verify the measurement results. Results show that the circuit model predicts the communication channel characteristics well at lower frequencies but cannot account for the influence of the measurement setup at higher frequencies. The influence of wire inductances, which can cause a resonant behavior when measuring at frequencies above 100 MHz, was observed using the FEM model. The results also show that the higher the conductivity of the tissue in which the device is implanted, the lower the gain of the signal, with the difference in gain being more prominent when capacitive termination with a high-impedance load is used instead of low-impedance termination. These findings provide valuable insight for selecting the appropriate interface (low-impedance vs. high-impedance termination) across specific frequency ranges for in-body to on-body (IB2OB) communication devices, while illustrating the effect of tissue conductivity on an IBC channel, thereby supporting the optimized design and implementation of reliable IB2OB communication systems.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-12-30
DOI
https://doi.org/10.3390/bioengineering13010042
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards Wideband Characterization and Modeling of In-Body to On-Body Intrabody Communication Channels

Yueming M. Gao, Željka Lučev Vasić, Matija Roglić
Bioengineering
Wireless Body Area Networks
article

Towards Wideband Characterization and Modeling of In-Body to On-Body Intrabody Communication Channels

Yueming M. Gao, Željka Lučev Vasić, Matija Roglić
article en

Abstract

Implantable intrabody communication (IBC) is a method that enables low-power, high-security communication between implanted in-body devices that could track biomedical signals and an on-body receiver by using the human body as a communication medium. As the human body consists of various tissues that each have different conductivity, this paper explores the effects of the conductivity of the communication medium on the channel gain over a wide frequency range from 10 MHz up to 300 MHz through the measurements and two models: an electrical circuit model and a FEM simulation model. Measurements are conducted using a liquid phantom with varying conductivity values from 0 S/m up to 1 S/m, covering most human tissues in the frequency range of interest. The circuit and FEM models are designed to mimic the measurement setup in order to verify the measurement results. Results show that the circuit model predicts the communication channel characteristics well at lower frequencies but cannot account for the influence of the measurement setup at higher frequencies. The influence of wire inductances, which can cause a resonant behavior when measuring at frequencies above 100 MHz, was observed using the FEM model. The results also show that the higher the conductivity of the tissue in which the device is implanted, the lower the gain of the signal, with the difference in gain being more prominent when capacitive termination with a high-impedance load is used instead of low-impedance termination. These findings provide valuable insight for selecting the appropriate interface (low-impedance vs. high-impedance termination) across specific frequency ranges for in-body to on-body (IB2OB) communication devices, while illustrating the effect of tissue conductivity on an IBC channel, thereby supporting the optimized design and implementation of reliable IB2OB communication systems.

BioengineeringVol. 13(1)
University of Zagreb (HR), Fuzhou University (CN)
Openalex Percentile: Top 41%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.