Kinetics and Fluid-Specific Behavior of Metal Ions After Hip Replacement

<b>Background</b>: Total hip arthroplasty (THA) is a well-tolerated and effective procedure that can improve a patient's mobility and quality of life. A main concern, however, is the release of metal ions into the body due to wear and corrosion. Commonly reported ions are Co and Cr, while others, such as Ti, Mo, and Ni, are less frequently studied. The objective of this study was to characterize compartmentalization and time-dependent ion behaviors across serum, whole blood, and urine after hip prosthetic implantation. The goal of using Random Forest (RF) was to determine whether machine learning modeling could support temporal trends across data. <b>Methods</b>: Data was gathered from the literature of clinical studies, and we conducted a pooled analysis of the temporal kinetics from cohorts of patients who received hip prosthetics. Mean ion concentrations were normalized to µg/L across each fluid and weighted by cohort sample size. RF was used as a study-level test of predictive accuracy across ions. <b>Results</b>: For serum and whole blood, Co and Cr displayed one-phase association models, while Ti showed an exponential rise and decay. Ions typically rose quickly within the first 24 months postoperatively. Serum Co and whole blood had similar patterns, tapering off just under 2 µg/L, but serum Cr (~2.02 µg/L) was generally higher than that of whole blood (~0.99 µg/L). Mean urinary Co levels were greater than those of Cr, suggesting a larger, freely filterable fraction for Co. RF was implemented to determine predictive accuracy for each ion, showing a stronger fit for Co (R<sup>2</sup> = 0.86, RMSE = 0.57) compared to Cr (R<sup>2</sup> = 0.52, RMSE = 0.50). <b>Conclusions</b>: Sub-threshold exposure was prevalent across cohorts. Serum and whole blood Co and Cr displayed distinct kinetic profiles and, if validated, could support fluid-specific monitoring strategies. We present a methodology for interpreting ion kinetics and show potential for machine learning applications in postoperative monitoring.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-12-30
DOI
https://doi.org/10.3390/bioengineering13010044
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Kinetics and Fluid-Specific Behavior of Metal Ions After Hip Replacement

Sheila Galbreath, Charles N. Thompson, Tarun Goswami, Samikshya Neupane
Bioengineering
Orthopaedic implants and arthroplasty
article

Kinetics and Fluid-Specific Behavior of Metal Ions After Hip Replacement

Sheila Galbreath, Charles N. Thompson, Tarun Goswami, Samikshya Neupane
article en

Abstract

<b>Background</b>: Total hip arthroplasty (THA) is a well-tolerated and effective procedure that can improve a patient's mobility and quality of life. A main concern, however, is the release of metal ions into the body due to wear and corrosion. Commonly reported ions are Co and Cr, while others, such as Ti, Mo, and Ni, are less frequently studied. The objective of this study was to characterize compartmentalization and time-dependent ion behaviors across serum, whole blood, and urine after hip prosthetic implantation. The goal of using Random Forest (RF) was to determine whether machine learning modeling could support temporal trends across data. <b>Methods</b>: Data was gathered from the literature of clinical studies, and we conducted a pooled analysis of the temporal kinetics from cohorts of patients who received hip prosthetics. Mean ion concentrations were normalized to µg/L across each fluid and weighted by cohort sample size. RF was used as a study-level test of predictive accuracy across ions. <b>Results</b>: For serum and whole blood, Co and Cr displayed one-phase association models, while Ti showed an exponential rise and decay. Ions typically rose quickly within the first 24 months postoperatively. Serum Co and whole blood had similar patterns, tapering off just under 2 µg/L, but serum Cr (~2.02 µg/L) was generally higher than that of whole blood (~0.99 µg/L). Mean urinary Co levels were greater than those of Cr, suggesting a larger, freely filterable fraction for Co. RF was implemented to determine predictive accuracy for each ion, showing a stronger fit for Co (R<sup>2</sup> = 0.86, RMSE = 0.57) compared to Cr (R<sup>2</sup> = 0.52, RMSE = 0.50). <b>Conclusions</b>: Sub-threshold exposure was prevalent across cohorts. Serum and whole blood Co and Cr displayed distinct kinetic profiles and, if validated, could support fluid-specific monitoring strategies. We present a methodology for interpreting ion kinetics and show potential for machine learning applications in postoperative monitoring.

BioengineeringVol. 13(1)
Wright State University (US)
Life in Land
Openalex Percentile: Top 25%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.