Low-Profile Altura® Endograft System Versus Standard-Profile Stent Grafts for Endovascular Aneurysm Repair: A Case-Matched Study

<b>Background/Objectives:</b> Endovascular aneurysm repair (EVAR) is currently the preferred method for treating abdominal aortic aneurysms (AAA) due to lower perioperative morbidity and mortality compared with open aortic repair (OAR). However, anatomical limitations such as narrow or tortuous iliac arteries may preclude EVAR. The low-profile Altura<sup>®</sup> stent graft (LPSG) was designed to overcome these limitations. This study aimed to compare the outcomes of Altura<sup>®</sup> low-profile endografts with standard-profile stent grafts (SPSGs) in AAA treatment. <b>Methods:</b> This single-center, retrospective, case-matched study included 30 patients treated with Altura<sup>®</sup> LPSG and 30 matched controls who underwent SPSG implantation between July 2021 and February 2023. Demographic, anatomical, operative, and postoperative parameters were analyzed. Follow-up was performed at 3, 6, and 12 months using ultrasound and computed tomography angiography (CTA). <b>Results:</b> Patients in the LPSG group more frequently had narrow access vessels (<6 mm, 46.7% vs. 3.3%, <i>p</i> = 0.001). The mean procedure time was shorter in the LPSG group (80 vs. 90 min, <i>p</i> = 0.04), and hospital stay was reduced (3 vs. 4 days, <i>p</i> = 0.03). No 30-day mortality occurred in either group. At 12 months, no aneurysm rupture, graft infection, or aneurysm-related death was observed. The rate of secondary interventions was comparable between groups. <b>Conclusions:</b> The low-profile Altura<sup>®</sup> stent graft provides a safe and effective option for AAA patients with narrow access vessels. Its bilateral parallel configuration and lack of gate cannulation simplify EVAR, shorten procedure time, and may be especially beneficial in emergency or anatomically challenging cases. Further prospective studies are warranted to confirm these findings.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-12-30
DOI
https://doi.org/10.3390/jcm15010293
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Profile Altura® Endograft System Versus Standard-Profile Stent Grafts for Endovascular Aneurysm Repair: A Case-Matched Study

Roger Marek Krzyżewski, Mateusz Rubinkiewicz, Marek Piwowarczyk, Katarzyna Zbierska-Rubinkiewicz et al.
Journal of Clinical Medicine
Aortic aneurysm repair treatments
article

Low-Profile Altura® Endograft System Versus Standard-Profile Stent Grafts for Endovascular Aneurysm Repair: A Case-Matched Study

Roger Marek Krzyżewski, Mateusz Rubinkiewicz, Marek Piwowarczyk, Katarzyna Zbierska-Rubinkiewicz, Jerzy Krzywoń, Hubert Kostka, Jeremy Jan Spula
article en

Abstract

<b>Background/Objectives:</b> Endovascular aneurysm repair (EVAR) is currently the preferred method for treating abdominal aortic aneurysms (AAA) due to lower perioperative morbidity and mortality compared with open aortic repair (OAR). However, anatomical limitations such as narrow or tortuous iliac arteries may preclude EVAR. The low-profile Altura<sup>®</sup> stent graft (LPSG) was designed to overcome these limitations. This study aimed to compare the outcomes of Altura<sup>®</sup> low-profile endografts with standard-profile stent grafts (SPSGs) in AAA treatment. <b>Methods:</b> This single-center, retrospective, case-matched study included 30 patients treated with Altura<sup>®</sup> LPSG and 30 matched controls who underwent SPSG implantation between July 2021 and February 2023. Demographic, anatomical, operative, and postoperative parameters were analyzed. Follow-up was performed at 3, 6, and 12 months using ultrasound and computed tomography angiography (CTA). <b>Results:</b> Patients in the LPSG group more frequently had narrow access vessels (<6 mm, 46.7% vs. 3.3%, <i>p</i> = 0.001). The mean procedure time was shorter in the LPSG group (80 vs. 90 min, <i>p</i> = 0.04), and hospital stay was reduced (3 vs. 4 days, <i>p</i> = 0.03). No 30-day mortality occurred in either group. At 12 months, no aneurysm rupture, graft infection, or aneurysm-related death was observed. The rate of secondary interventions was comparable between groups. <b>Conclusions:</b> The low-profile Altura<sup>®</sup> stent graft provides a safe and effective option for AAA patients with narrow access vessels. Its bilateral parallel configuration and lack of gate cannulation simplify EVAR, shorten procedure time, and may be especially beneficial in emergency or anatomically challenging cases. Further prospective studies are warranted to confirm these findings.

Journal of Clinical MedicineVol. 15(1)
Jagiellonian University (PL), Krakow Cardiovascular Research Institute (PL)
Good health and well-being
Openalex Percentile: Top 27%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.