The <scp>CFD</scp> investigation of optimized design of a solar still coupled with a condenser chamber

Abstract This study focuses on optimizing the condenser chamber design in solar stills to enhance freshwater production. A two‐dimensional numerical model simulates a solar still with a condenser, considering humid air as an ideal gas. The model analyzes the impact of three key geometric parameters: condenser depth, height, and surface area, on both freshwater yield and flow patterns. Given space constraints in carrying out the projects, condenser depth was limited to the device's shadow to ensure a consistently cold condenser surface. The model demonstrates good agreement with experimental data for single‐slope solar stills, achieving a maximum error of 1%. This accuracy surpasses previously reported models. Building upon prior research suggesting that condenser chambers can increase freshwater yield by up to 43% compared to conventional designs, this study utilizes CFD simulations to validate this finding. This simulation predict a 44% improvement with a 2% error, further supporting the benefits of condenser chambers. The results shows that the optimal values of parameters are interdependent, meaning that the optimal value of one parameter is contingent upon the values of other parameters. The simulations predicted a maximum total freshwater yield of 1.12 kg/m 2 h with 0.85 kg/m 2 h condensing directly on the glass cover at = 0.63 while equals to H 1 and is considered constant. Additionally, the proposed design considerations, which prioritize a larger vertical distance and depth of the condenser from the water surface, promote vapor capture within the system while maintaining cost‐effective construction.

Authors

Institutions

Publication Details

Journal
Environmental Progress & Sustainable Energy
Published
2025-12-31
DOI
https://doi.org/10.1002/ep.70280
Primary Topic
Solar-Powered Water Purification Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The CFD investigation of optimized design of a solar still coupled with a condenser chamber

M. Abolhasannejad, J. A. Esfahani, S. A. Fanaee
Environmental Progress & Sustainable Energy
Solar-Powered Water Purification Methods
article

The CFD investigation of optimized design of a solar still coupled with a condenser chamber

M. Abolhasannejad, J. A. Esfahani, S. A. Fanaee
article en

Abstract

Abstract This study focuses on optimizing the condenser chamber design in solar stills to enhance freshwater production. A two‐dimensional numerical model simulates a solar still with a condenser, considering humid air as an ideal gas. The model analyzes the impact of three key geometric parameters: condenser depth, height, and surface area, on both freshwater yield and flow patterns. Given space constraints in carrying out the projects, condenser depth was limited to the device's shadow to ensure a consistently cold condenser surface. The model demonstrates good agreement with experimental data for single‐slope solar stills, achieving a maximum error of 1%. This accuracy surpasses previously reported models. Building upon prior research suggesting that condenser chambers can increase freshwater yield by up to 43% compared to conventional designs, this study utilizes CFD simulations to validate this finding. This simulation predict a 44% improvement with a 2% error, further supporting the benefits of condenser chambers. The results shows that the optimal values of parameters are interdependent, meaning that the optimal value of one parameter is contingent upon the values of other parameters. The simulations predicted a maximum total freshwater yield of 1.12 kg/m 2 h with 0.85 kg/m 2 h condensing directly on the glass cover at = 0.63 while equals to H 1 and is considered constant. Additionally, the proposed design considerations, which prioritize a larger vertical distance and depth of the condenser from the water surface, promote vapor capture within the system while maintaining cost‐effective construction.

Environmental Progress & Sustainable EnergyVol. 45(2)
Lishui University (CN), Ferdowsi University of Mashhad (IR), University of Birjand (IR)
Openalex Percentile: Top 51%
Solar-Powered Water Purification Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The <scp>CFD</scp> investigation of optimized design of a solar still coupled with a condenser chamber — M. Abolhasannejad, J. A. Esfahani, et al. · Environmental Progress & Sustainable Energy (2025) | TGRS Research Map | TGRS