Interplay between corneal oxygenation and swelling for scleral lens–a modelling approach

• 2-D Modelling of corneal oxygenation as a tool for predicting the cornea swelling. • The model takes into account of the coupling between the oxygen transfer and the corneal metabolism. • The lens decentring, that causes a reduction of oxygen rate is investigating using the 2-D model. • The parameters included in the model are determined using experimental measurements (using OCT technology). In this study, a mathematical model was developed that incorporates a coupling between mass transfer and corneal metabolism to predict corneal oxygenation with scleral lenses. The implementation of lens wear was achieved through the use of two distinct 2D geometries, each characterized by a unique central clearance (271 µm and 573 µm, respectively), as measured by means of OCT technology. The variation in tear film (also called tear reservoir) thickness in conjunction with the lens was found to induce a shift in corneal metabolism from the aerobic to the anaerobic pathway. This shift in oxygen transfer rate to the cornea is predicted to result in local corneal swelling. The numerical model demonstrated that enhancing lens permeability leads to an increase in corneal oxygenation; however, this gain is constrained by the tear reservoir's oxygen transfer resistance. Furthermore, with lens decentration, oxygenation exhibited an increase in the upper part of the cornea, while it decreased in the lower part, owing to the tear reservoir thickness variation with lens decentration. However, the oxygen demand and the tear reservoir thickness at the central part of the cornea exhibited only very small variation with decentration.

Authors

Institutions

Publication Details

Journal
Chemical Engineering Journal Advances
Published
2025-12-31
DOI
https://doi.org/10.1016/j.ceja.2025.101028
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interplay between corneal oxygenation and swelling for scleral lens–a modelling approach

Emmanuel Veillard, Peter Biermans, Denis Bouyer, Luc Mezenge et al.
Chemical Engineering Journal Advances
Ocular Surface and Contact Lens
article

Interplay between corneal oxygenation and swelling for scleral lens–a modelling approach

Emmanuel Veillard, Peter Biermans, Denis Bouyer, Luc Mezenge, Christophe Charmette, Laure ADAM, Ahmed JARBOUI, Jean-Pierre MERICQ, Thierry THAMI
article en

Abstract

• 2-D Modelling of corneal oxygenation as a tool for predicting the cornea swelling. • The model takes into account of the coupling between the oxygen transfer and the corneal metabolism. • The lens decentring, that causes a reduction of oxygen rate is investigating using the 2-D model. • The parameters included in the model are determined using experimental measurements (using OCT technology). In this study, a mathematical model was developed that incorporates a coupling between mass transfer and corneal metabolism to predict corneal oxygenation with scleral lenses. The implementation of lens wear was achieved through the use of two distinct 2D geometries, each characterized by a unique central clearance (271 µm and 573 µm, respectively), as measured by means of OCT technology. The variation in tear film (also called tear reservoir) thickness in conjunction with the lens was found to induce a shift in corneal metabolism from the aerobic to the anaerobic pathway. This shift in oxygen transfer rate to the cornea is predicted to result in local corneal swelling. The numerical model demonstrated that enhancing lens permeability leads to an increase in corneal oxygenation; however, this gain is constrained by the tear reservoir's oxygen transfer resistance. Furthermore, with lens decentration, oxygenation exhibited an increase in the upper part of the cornea, while it decreased in the lower part, owing to the tear reservoir thickness variation with lens decentration. However, the oxygen demand and the tear reservoir thickness at the central part of the cornea exhibited only very small variation with decentration.

Chemical Engineering Journal AdvancesVol. 25
École Nationale Supérieure de Chimie de Montpellier (FR), Centre National de la Recherche Scientifique (FR), Université de Montpellier (FR), Institut Européen des Membranes (FR), L.Garde (United States) (US), Philips (France) (FR)
Openalex Percentile: Top 25%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.