The effect of the design of the abutment screw on the loosening force

This study aimed to assess the stability of the screw joint by comparing the implant abutment screw with a Morse-tapered design in the head with the existing implant abutment screw with a butt joint design.After the implant was fastened with either a support screw with a Morse-tapered design or an abutment screw with a butt-joint design, the specimens were divided into six groups.The nonloaded specimens were assigned to two groups: Group 1 (Morse taper) and Group 2 (butt joint).The specimens subjected to 100,000 loading cycles were assigned to Groups 3 and 4. Those subjected to 500,000 loading cycles were assigned to Groups 5 and 6.Each abutment screw was tightened to 35 Ncm.For Groups 1 and 2, the removal torque was measured 1 hour after tightening.For the other four groups, prostheses were fabricated and connected, and a cyclic loading of 50 N was applied before measuring the removal torque.The mean removal torques for Groups 1-6 were 34.241.67,27.300.74,31.801.61,27.200.93,32.820.90, and 26.841.39Ncm, respectively.Under all loading conditions, the abutment screws with the Morse-tapered design showed a higher mean removal torque than those with the butt-joint design.Implants assembled with abutment screws having a Morse-tapered connection design showed greater stability than those with a conventional butt-joint connection design.

Authors

Institutions

Publication Details

Journal
Oral Biology Research
Published
2025-12-31
DOI
https://doi.org/10.21851/obr.25.032
Primary Topic
Geotechnical Engineering and Soil Mechanics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of the design of the abutment screw on the loosening force

Tae-Hun Kim, Young-Hun Kwak, Hee Jung Kim, Soo-Yeon Lee
Oral Biology Research
Geotechnical Engineering and Soil Mechanics
article

The effect of the design of the abutment screw on the loosening force

Tae-Hun Kim, Young-Hun Kwak, Hee Jung Kim, Soo-Yeon Lee
article en

Abstract

This study aimed to assess the stability of the screw joint by comparing the implant abutment screw with a Morse-tapered design in the head with the existing implant abutment screw with a butt joint design.After the implant was fastened with either a support screw with a Morse-tapered design or an abutment screw with a butt-joint design, the specimens were divided into six groups.The nonloaded specimens were assigned to two groups: Group 1 (Morse taper) and Group 2 (butt joint).The specimens subjected to 100,000 loading cycles were assigned to Groups 3 and 4. Those subjected to 500,000 loading cycles were assigned to Groups 5 and 6.Each abutment screw was tightened to 35 Ncm.For Groups 1 and 2, the removal torque was measured 1 hour after tightening.For the other four groups, prostheses were fabricated and connected, and a cyclic loading of 50 N was applied before measuring the removal torque.The mean removal torques for Groups 1-6 were 34.241.67,27.300.74,31.801.61,27.200.93,32.820.90, and 26.841.39Ncm, respectively.Under all loading conditions, the abutment screws with the Morse-tapered design showed a higher mean removal torque than those with the butt-joint design.Implants assembled with abutment screws having a Morse-tapered connection design showed greater stability than those with a conventional butt-joint connection design.

Oral Biology ResearchVol. 49
Chosun University (KR)
Chosun University, Chosun University Dental Hospital
Sustainable cities and communities
Openalex Percentile: Top 35%
Geotechnical Engineering and Soil Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The effect of the design of the abutment screw on the loosening force — Tae-Hun Kim, Young-Hun Kwak, et al. · Oral Biology Research (2025) | TGRS Research Map | TGRS