Analysis of M-EDI and Visual Metrics According to Pendant Lighting Conditions: A Comparison with Flat Panel Fixtures

This study investigates how the mounting height and direct–indirect light ratio of pendant luminaires affect non-visual lighting performance(M-EDI, Melanopic Equivalent Daylight Illuminance) and visual metrics(UGR, uniformity, etc.) in a small office, compared to flat panel luminaires. Relux-based simulations were conducted with horizontal illuminance(Eh) normalized to 500lx. Among the 28 pendant lighting scenarios, 11 met the M-EDI ≥ 250lx criterion; however, 6 were excluded because they required luminous flux beyond the rated 4,100lm. The compliant 5 scenarios showed high Ev/Eh ratios(0.74–0.95) but also high UGR values(25.2–25.6), exceeding the office recommendation(UGR ≤ 19). In contrast, flat panel luminaires did not meet the M-EDI criterion(250lx) but exhibited UGR values that met or neared the threshold. These results reveal a trade-off between visual comfort and non-visual performance, indicating that hybrid lighting strategies combining both luminaire types may be necessary.

Authors

Publication Details

Journal
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
Published
2025-12-30
DOI
https://doi.org/10.5207/jieie.2025.39.6.435
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of M-EDI and Visual Metrics According to Pendant Lighting Conditions: A Comparison with Flat Panel Fixtures

An-Seop Choi, Younjoo Cho
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
Building Energy and Comfort Optimization
article

Analysis of M-EDI and Visual Metrics According to Pendant Lighting Conditions: A Comparison with Flat Panel Fixtures

An-Seop Choi, Younjoo Cho
article en

Abstract

This study investigates how the mounting height and direct–indirect light ratio of pendant luminaires affect non-visual lighting performance(M-EDI, Melanopic Equivalent Daylight Illuminance) and visual metrics(UGR, uniformity, etc.) in a small office, compared to flat panel luminaires. Relux-based simulations were conducted with horizontal illuminance(Eh) normalized to 500lx. Among the 28 pendant lighting scenarios, 11 met the M-EDI ≥ 250lx criterion; however, 6 were excluded because they required luminous flux beyond the rated 4,100lm. The compliant 5 scenarios showed high Ev/Eh ratios(0.74–0.95) but also high UGR values(25.2–25.6), exceeding the office recommendation(UGR ≤ 19). In contrast, flat panel luminaires did not meet the M-EDI criterion(250lx) but exhibited UGR values that met or neared the threshold. These results reveal a trade-off between visual comfort and non-visual performance, indicating that hybrid lighting strategies combining both luminaire types may be necessary.

Journal of the Korean Institute of Illuminating and Electrical Installation EngineersVol. 39(6)
Openalex Percentile: Top 37%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.