Topology Reduction for Determining Worst-Case Attacks in Radially Operated Distribution Networks

With the increasing digitalization of the power system, cyber attacks that threaten physical disruption, such as power outages, are increasing. Hence, understanding system resilience and the operator responses is crucial for anticipating and mitigating threats that may cause outages through power line disconnections. A common approach to assessing grid resilience is to consider the worst-case attack, in which the attack is assumed to maximize the potential damage while the operators react to minimize such loss. This assessment, however, can have a vast number of possible actions by the attacker as the size of the power network and the severity of the attack increase, making it computationally expensive. We propose a topology reduction technique on radially operated distribution networks, which reduces the set of lines to be considered in the worst-case attack. The reduced network can determine such an attack more efficiently compared to the original network. Case studies on 33- and 119-bus systems showed that the introduced method reduced the network sizes by 25% and 38%, respectively, and its effectiveness on the worst-case attack computation increased as larger attacks with more line disconnections were considered.

Authors

Institutions

Publication Details

Published
2025-10-20
DOI
https://doi.org/10.1109/isgteurope64741.2025.11305373
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Topology Reduction for Determining Worst-Case Attacks in Radially Operated Distribution Networks

Han La Poutré, Sho Cremers, Marten van Dijk
Smart Grid Security and Resilience
article

Topology Reduction for Determining Worst-Case Attacks in Radially Operated Distribution Networks

Han La Poutré, Sho Cremers, Marten van Dijk
article en

Abstract

With the increasing digitalization of the power system, cyber attacks that threaten physical disruption, such as power outages, are increasing. Hence, understanding system resilience and the operator responses is crucial for anticipating and mitigating threats that may cause outages through power line disconnections. A common approach to assessing grid resilience is to consider the worst-case attack, in which the attack is assumed to maximize the potential damage while the operators react to minimize such loss. This assessment, however, can have a vast number of possible actions by the attacker as the size of the power network and the severity of the attack increase, making it computationally expensive. We propose a topology reduction technique on radially operated distribution networks, which reduces the set of lines to be considered in the worst-case attack. The reduced network can determine such an attack more efficiently compared to the original network. Case studies on 33- and 119-bus systems showed that the introduced method reduced the network sizes by 25% and 38%, respectively, and its effectiveness on the worst-case attack computation increased as larger attacks with more line disconnections were considered.

Centrum Wiskunde & Informatica (NL)
Openalex Percentile: Top 35%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.