High social support is associated with reduced cardiac events in patients following ICD/CRT-D implantation: a one-year follow-up study in China

Few studies exist on the impact of social support on cardiac events following implantation of implantable cardioverter-defibrillators (ICD) or cardiac resynchronization therapy devices with defibrillators (CRT-D). This study aims to investigate the longitudinal association between social support and adverse cardiac events among ICD/CRT-D recipients during a 1-year follow-up. This hospital-based longitudinal study included 101 patients undergoing first ICD/CRT-D implantation. Demographic and clinical data were collected as confounders. Social support, anxiety, and depression scores were assessed at baseline and during follow-ups (1, 3, 6, 12 months). Cardiac events (primary endpoint: all-cause mortality or appropriate ICD shocks; secondary endpoint: primary endpoint events, heart failure hospitalization, or acute coronary syndrome) were documented. Kaplan-Meier analyses and Cox proportional hazards models (adjusted for age, sex, NYHA class, and ICD indication) evaluated associations, while time-dependent Cox models analyzed temporal effects. Patients with higher baseline social support exhibited a reduced risk of the primary composite endpoint (log-rank χ² = 5.53, p = 0.019) and secondary composite endpoint (log-rank χ² = 14.64, p < 0.001). After multivariable adjustment (age, sex, NYHA class, ICD indication, anxiety/depression scores), high social support was independently linked to 65.6% lower secondary endpoint risk (adjusted HR = 0.344, 95% CI: 0.172–0.688, p = 0.003). The protective association attenuated over time (HR = 0.991 per unit time, p = 0.009) but remained statistically significant. Anxiety and depression showed no baseline association with events but demonstrated a time-dependent risk increase. Higher social support is independently associated with a reduced risk of the secondary composite endpoint after ICD/CRT-D implantation. Sustained psychosocial interventions may be warranted to mitigate long-term risk attenuation.

Authors

Institutions

Publication Details

Journal
BMC Psychology
Published
2025-12-30
DOI
https://doi.org/10.1186/s40359-025-03912-5
Primary Topic
Cardiac Health and Mental Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High social support is associated with reduced cardiac events in patients following ICD/CRT-D implantation: a one-year follow-up study in China

H. Cai, Hu Zhao, M. ZHANG, Jing Pan et al.
BMC Psychology
Cardiac Health and Mental Health
article

High social support is associated with reduced cardiac events in patients following ICD/CRT-D implantation: a one-year follow-up study in China

H. Cai, Hu Zhao, M. ZHANG, Jing Pan, Shaoshan Pang, Si Lu, Lirui Yu
article en

Abstract

Few studies exist on the impact of social support on cardiac events following implantation of implantable cardioverter-defibrillators (ICD) or cardiac resynchronization therapy devices with defibrillators (CRT-D). This study aims to investigate the longitudinal association between social support and adverse cardiac events among ICD/CRT-D recipients during a 1-year follow-up. This hospital-based longitudinal study included 101 patients undergoing first ICD/CRT-D implantation. Demographic and clinical data were collected as confounders. Social support, anxiety, and depression scores were assessed at baseline and during follow-ups (1, 3, 6, 12 months). Cardiac events (primary endpoint: all-cause mortality or appropriate ICD shocks; secondary endpoint: primary endpoint events, heart failure hospitalization, or acute coronary syndrome) were documented. Kaplan-Meier analyses and Cox proportional hazards models (adjusted for age, sex, NYHA class, and ICD indication) evaluated associations, while time-dependent Cox models analyzed temporal effects. Patients with higher baseline social support exhibited a reduced risk of the primary composite endpoint (log-rank χ² = 5.53, p = 0.019) and secondary composite endpoint (log-rank χ² = 14.64, p < 0.001). After multivariable adjustment (age, sex, NYHA class, ICD indication, anxiety/depression scores), high social support was independently linked to 65.6% lower secondary endpoint risk (adjusted HR = 0.344, 95% CI: 0.172–0.688, p = 0.003). The protective association attenuated over time (HR = 0.991 per unit time, p = 0.009) but remained statistically significant. Anxiety and depression showed no baseline association with events but demonstrated a time-dependent risk increase. Higher social support is independently associated with a reduced risk of the secondary composite endpoint after ICD/CRT-D implantation. Sustained psychosocial interventions may be warranted to mitigate long-term risk attenuation.

BMC PsychologyVol. 14(1)
Kunming Medical University (CN), First Affiliated Hospital of Kunming Medical University (CN)
Good health and well-being
Openalex Percentile: Top 30%
Cardiac Health and Mental Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.