In-depth Analysis of the Control Unit for Multiple Voltage Rails to Drive a Variety of ICs

Generating a negative output voltage rail from a positive input voltage is possible by reconfiguring an ordinary buck regulator into an inverting buck-boost (IBB) topology.Rather than operating considerations such as voltage and current stresses, the main challenge associated with this transformation arises from differences in the small-signal closed-loop characteristics.The most critical distinction is the presence of a right-half-plane (RHP) zero in the control-to-output transfer function of the IBB, which introduces non-minimum-phase behaviour, reduces the achievable phase margin, and may lead to instability and poor load transient response.For conventional PI controllers, the buck and IBB converters resulted in settling times of 5.0 ms and 6.8 ms, with overshoots of 13.65% and 8.46%, respectively, thus demonstrating the performance limitations of fixed-gain designs.As a solution, an auto-tuned PI controller with adaptive features has been proposed, which operates effectively in both the buck and IBB topologies.The proposed scheme achieves a significantly faster settling time of 2.27 ms with overshoot and undershoot below 2%, thereby ensuring superior robustness and dynamic performance compared to conventional approaches.

Authors

Institutions

Publication Details

Journal
Tehnicki vjesnik - Technical Gazette
Published
2025-12-30
DOI
https://doi.org/10.17559/tv-20250524002695
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-depth Analysis of the Control Unit for Multiple Voltage Rails to Drive a Variety of ICs

Aytaç Altan, Cağfer Yanarateş
Tehnicki vjesnik - Technical Gazette
Advanced DC-DC Converters
article

In-depth Analysis of the Control Unit for Multiple Voltage Rails to Drive a Variety of ICs

Aytaç Altan, Cağfer Yanarateş
article en

Abstract

Generating a negative output voltage rail from a positive input voltage is possible by reconfiguring an ordinary buck regulator into an inverting buck-boost (IBB) topology.Rather than operating considerations such as voltage and current stresses, the main challenge associated with this transformation arises from differences in the small-signal closed-loop characteristics.The most critical distinction is the presence of a right-half-plane (RHP) zero in the control-to-output transfer function of the IBB, which introduces non-minimum-phase behaviour, reduces the achievable phase margin, and may lead to instability and poor load transient response.For conventional PI controllers, the buck and IBB converters resulted in settling times of 5.0 ms and 6.8 ms, with overshoots of 13.65% and 8.46%, respectively, thus demonstrating the performance limitations of fixed-gain designs.As a solution, an auto-tuned PI controller with adaptive features has been proposed, which operates effectively in both the buck and IBB topologies.The proposed scheme achieves a significantly faster settling time of 2.27 ms with overshoot and undershoot below 2%, thereby ensuring superior robustness and dynamic performance compared to conventional approaches.

Tehnicki vjesnik - Technical GazetteVol. 33(1)
Gümüşhane University (TR), Zonguldak Bülent Ecevit University (TR)
Openalex Percentile: Top 41%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In-depth Analysis of the Control Unit for Multiple Voltage Rails to Drive a Variety of ICs — Aytaç Altan, Cağfer Yanarateş · Tehnicki vjesnik - Technical Gazette (2025) | TGRS Research Map | TGRS