Switch Open Fault Detection Method of Asymmetric Six-phase Permanent Magnet Synchronous Motors Using DC-Link Current Ripple Analysis

This paper proposes a switch open fault detection method for a dual three-phase inverter system by using the DC-link current ripple analysis in an asymmetric six-phase permanent magnet synchronous motor (PMSM). When a switch open fault occurs, specific ripple components appear in the DC-link current at either the fundamental or double the fundamental frequency, depending on the type of open fault. To extract these ripple components, the proposed method applies a variable high-pass filter (VHPF), followed by a variable all-pass filter (VAPF) to introduce a 90-degree phase shift and enable peak value estimation. A low-pass filter (LPF) is then used to suppress high-frequency noise, and correlation analysis with phase current signals is conducted to detect the fault. The proposed algorithm requires no additional hardware and has been experimentally validated using a propeller benchmark system. The experimental results demonstrate its effectiveness in identifying not only the occurrence of faults but also the specific faulty phase.

Authors

Publication Details

Journal
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
Published
2025-12-30
DOI
https://doi.org/10.5207/jieie.2025.39.6.453
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Switch Open Fault Detection Method of Asymmetric Six-phase Permanent Magnet Synchronous Motors Using DC-Link Current Ripple Analysis

Jae-Sung Heo, Sunghwan Hwang, So-Young Jun, Byeung-Jun Lim
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
Multilevel Inverters and Converters
article

Switch Open Fault Detection Method of Asymmetric Six-phase Permanent Magnet Synchronous Motors Using DC-Link Current Ripple Analysis

Jae-Sung Heo, Sunghwan Hwang, So-Young Jun, Byeung-Jun Lim
article en

Abstract

This paper proposes a switch open fault detection method for a dual three-phase inverter system by using the DC-link current ripple analysis in an asymmetric six-phase permanent magnet synchronous motor (PMSM). When a switch open fault occurs, specific ripple components appear in the DC-link current at either the fundamental or double the fundamental frequency, depending on the type of open fault. To extract these ripple components, the proposed method applies a variable high-pass filter (VHPF), followed by a variable all-pass filter (VAPF) to introduce a 90-degree phase shift and enable peak value estimation. A low-pass filter (LPF) is then used to suppress high-frequency noise, and correlation analysis with phase current signals is conducted to detect the fault. The proposed algorithm requires no additional hardware and has been experimentally validated using a propeller benchmark system. The experimental results demonstrate its effectiveness in identifying not only the occurrence of faults but also the specific faulty phase.

Journal of the Korean Institute of Illuminating and Electrical Installation EngineersVol. 39(6)
Openalex Percentile: Top 41%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.