Development, Validation, and Stability Assessment of High-performanceLiquid Chromatography Method for Rotigotine in PharmaceuticalApplications

Introduction: This study aimed to develop and validate a stability-indicating HPLC method for the quantification of Rotigotine, a dopamine receptor agonist used in the treatment of Parkinson’s disease, in compliance with ICH Q2(R1) guidelines. Methods: Chromatographic separation was achieved on a Shim-pack Solar C8 column (4.6 × 250 mm, 5 µm) using a mixture of acetonitrile and phosphate buffer (60:40, pH 4.5) with UV detection at 224 nm. Validation parameters included linearity, accuracy, precision, robustness, sensitivity, forced degradation studies, stability testing, and artificial plasma spiking. Results: The method was linear (1–15 µg/mL, r² = 0.9996) with high precision (%RSD < 0.5) and accuracy (98–102% recovery). LOD and LOQ were 0.575 µg/mL and 1.742 µg/mL, respectively. Forced degradation revealed significant instability under alkaline (39.22%) and oxidative (34.44%) stress, moderate degradation in acidic medium (15.1%), and minimal photolytic degradation (3.62%). Stability studies showed unacceptable degradation beyond 12 hours at room temperature. Plasma spiking confirmed applicability with recoveries up to 88.5% Discussion: The method demonstrated high sensitivity, reproducibility, and stability-indicating capability, highlighting Rotigotine’s vulnerability to alkaline and oxidative environments while confirming light stability and moderate acid sensitivity. Plasma recovery supports pharmacokinetic application. Conclusion: The validated HPLC method is robust and reliable for routine quality control, stability testing, and pharmacokinetic evaluation of Rotigotine, with storage conditions requiring strict control to maintain drug integrity

Authors

Institutions

Publication Details

Journal
Current Spectroscopy and Chromatography
Published
2025-12-19
DOI
https://doi.org/10.2174/0129504910428974251104051036
Primary Topic
Parkinson's Disease Mechanisms and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development, Validation, and Stability Assessment of High-performanceLiquid Chromatography Method for Rotigotine in PharmaceuticalApplications

Deepti Pandita, Dalapathi Gugulothu, Surajpal Verma, Ashwani
Current Spectroscopy and Chromatography
Parkinson's Disease Mechanisms and Treatments
article

Development, Validation, and Stability Assessment of High-performanceLiquid Chromatography Method for Rotigotine in PharmaceuticalApplications

Deepti Pandita, Dalapathi Gugulothu, Surajpal Verma, Ashwani
article en

Abstract

Introduction: This study aimed to develop and validate a stability-indicating HPLC method for the quantification of Rotigotine, a dopamine receptor agonist used in the treatment of Parkinson’s disease, in compliance with ICH Q2(R1) guidelines. Methods: Chromatographic separation was achieved on a Shim-pack Solar C8 column (4.6 × 250 mm, 5 µm) using a mixture of acetonitrile and phosphate buffer (60:40, pH 4.5) with UV detection at 224 nm. Validation parameters included linearity, accuracy, precision, robustness, sensitivity, forced degradation studies, stability testing, and artificial plasma spiking. Results: The method was linear (1–15 µg/mL, r² = 0.9996) with high precision (%RSD < 0.5) and accuracy (98–102% recovery). LOD and LOQ were 0.575 µg/mL and 1.742 µg/mL, respectively. Forced degradation revealed significant instability under alkaline (39.22%) and oxidative (34.44%) stress, moderate degradation in acidic medium (15.1%), and minimal photolytic degradation (3.62%). Stability studies showed unacceptable degradation beyond 12 hours at room temperature. Plasma spiking confirmed applicability with recoveries up to 88.5% Discussion: The method demonstrated high sensitivity, reproducibility, and stability-indicating capability, highlighting Rotigotine’s vulnerability to alkaline and oxidative environments while confirming light stability and moderate acid sensitivity. Plasma recovery supports pharmacokinetic application. Conclusion: The validated HPLC method is robust and reliable for routine quality control, stability testing, and pharmacokinetic evaluation of Rotigotine, with storage conditions requiring strict control to maintain drug integrity

Current Spectroscopy and ChromatographyVol. 11
Delhi Pharmaceutical Science and Research University (IN)
Openalex Percentile: Top 30%
Parkinson's Disease Mechanisms and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development, Validation, and Stability Assessment of High-performanceLiquid Chromatography Method for Rotigotine in PharmaceuticalApplications — Deepti Pandita, Dalapathi Gugulothu, et al. · Current Spectroscopy and Chromatography (2025) | TGRS Research Map | TGRS