Contextualizing Equivalent Clean Airflow Rates for Airborne Pathogens of Ionizers and Other Electronic Indoor Air Cleaners

Additive electronic air cleaners like ionizers, photocatalytic oxidizers, and plasma devices intentionally release reactive species into indoor air so that they may inactivate infectious airborne pathogens. Third-party commercial testing and peer-reviewed studies alike typically report inactivation metrics in terms of percent- or log-reductions observed from chamber experiments that imply a nearly complete elimination of infection risks. However, these metrics are highly dependent upon the experimental volume and duration, so they do not directly translate to actual effectiveness indoors. We reviewed 45 experiments across 14 published studies and converted reported reduction metrics into equivalent clean airflow rates (ECA). Different studies yielded distinct ECA distributions, suggesting that differences in experimental procedures, device specifications, or environmental conditions may be more important ECA determinants than the target pathogen or the underlying device technology. Study-averaged ECAs spanned between 1.4 and 134 m3/h, with the median study having an average ECA = 31 m3/h. Even small off-the-shelf HEPA-filter air cleaners typically provide ECAs that exceed the best-performing additive devices analyzed herein. Their low efficacy relative to alternatives, environmental factors that can affect performance, and chemical byproduct concerns are discussed in the context of test standard development and system selection.

Authors

Institutions

Publication Details

Journal
Environmental Science & Technology Letters
Published
2025-12-30
DOI
https://doi.org/10.1021/acs.estlett.5c01201
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contextualizing Equivalent Clean Airflow Rates for Airborne Pathogens of Ionizers and Other Electronic Indoor Air Cleaners

Charles Nathan Haas, Michael S. Waring, Bryan E. Cummings, John G. Williams
Environmental Science & Technology Letters
Infection Control and Ventilation
article

Contextualizing Equivalent Clean Airflow Rates for Airborne Pathogens of Ionizers and Other Electronic Indoor Air Cleaners

Charles Nathan Haas, Michael S. Waring, Bryan E. Cummings, John G. Williams
article en

Abstract

Additive electronic air cleaners like ionizers, photocatalytic oxidizers, and plasma devices intentionally release reactive species into indoor air so that they may inactivate infectious airborne pathogens. Third-party commercial testing and peer-reviewed studies alike typically report inactivation metrics in terms of percent- or log-reductions observed from chamber experiments that imply a nearly complete elimination of infection risks. However, these metrics are highly dependent upon the experimental volume and duration, so they do not directly translate to actual effectiveness indoors. We reviewed 45 experiments across 14 published studies and converted reported reduction metrics into equivalent clean airflow rates (ECA). Different studies yielded distinct ECA distributions, suggesting that differences in experimental procedures, device specifications, or environmental conditions may be more important ECA determinants than the target pathogen or the underlying device technology. Study-averaged ECAs spanned between 1.4 and 134 m3/h, with the median study having an average ECA = 31 m3/h. Even small off-the-shelf HEPA-filter air cleaners typically provide ECAs that exceed the best-performing additive devices analyzed herein. Their low efficacy relative to alternatives, environmental factors that can affect performance, and chemical byproduct concerns are discussed in the context of test standard development and system selection.

Environmental Science & Technology LettersVol. 13(1)
Harris Health System (US), Harrison Medical Center (US), Drexel University (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 27%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Contextualizing Equivalent Clean Airflow Rates for Airborne Pathogens of Ionizers and Other Electronic Indoor Air Cleaners — Charles Nathan Haas, Michael S. Waring, et al. · Environmental Science & Technology Letters (2025) | TGRS Research Map | TGRS