Efficacy and safety of the SoniCracker intravascular lithotripsy device for severely calcified coronary lesions: the LEAD-FIM study from China
Calcified lesions represent a key challenge in percutaneous coronary intervention (PCI). In recent years, intravascular lithotripsy (IVL) has emerged as a safe and effective adjunctive therapy for severely calcified lesions before stenting implantation. In the present study, we investigated the safety and efficacy of a novel coronary IVL system in patients with severely calcified lesions. The LEAD-FIM study was a prospective, multicenter, single-arm trial in China. Patients with severely calcified lesions and a clinical indication for PCI with vessel preparation for DES implantation using IVL. The primary endpoint was procedural success, which was defined as residual stenosis ≤ 30% following successful stent placement and the absence of major adverse cardiac event (MACE, including cardiac death, myocardial infarction, or target vessel revascularization) up to 7 days post-procedure. The primary endpoint assessed against performance goals derived from major published registries on Shockwave IVL. A subgroup analysis using optical coherence tomography was carried out to evaluate the morphology of calcification before and after IVL treatment, as well as post-stent. From February to April 2023, a total of 184 patients with severely calcified lesions at 11 sites were enrolled. The target lesions were predominantly in the left anterior descending artery (77.2%) and the mean diameter stenosis was 87.6%±6.6%. Procedure success was observed in 96.7% (178/184) of patients (95%CI: 94.2%-99.3%), which significantly surpassed the prespecified performance goal of 85.0% (p < 0.001). All patients met the criteria of angiographic success and 6 (3.3%) patients occurred in-hospital MACE event. The rate of 30-day and 180-day MACE was 3.8% (7/184) and 4.9% (9/184), respectively. In the OCT sub-study population, minimum lumen area increased after IVL by 1.22 ± 0.87 mm² and by an additional 2.54 ± 1.73 mm² post stenting with overall stent expansion of 85.3 ± 17.1% at the site of maximal calcification. No serious adverse events associated with the device were documented. The rates of target lesion failure at 1- and 6-month were 3.3% and 4.4%, respectively. The novel IVL system could promote stent delivery and achieve optimized stent expansion among patients with severely calcified coronary lesions. This trial was registered in the clinicaltrials.gov (URL: https://www.clinicaltrials.gov; Unique identifier: NCT05649488) on 28th November 2022.
Authors
- Y L Han
- Ping Zhang
- Qin Qin (ORCID: https://orcid.org/0000-0002-3497-5557)
- Ziliang Bai
- Qian Tong (ORCID: https://orcid.org/0000-0001-9098-1989)
- Yifan He (ORCID: https://orcid.org/0009-0001-8664-037X)
- Zhixiong Zhong
- Haiwei Liu
- Jiancheng Xiu
- Jun Zhang
- Wei Liu
- Shaobin Jia
- Quanmin Jing
Institutions
- Jilin University (CN)
- Peking University (CN)
- Sichuan University (CN)
- Northern Hospital (AU)
- Beijing Jishuitan Hospital (CN)
- Meizhou City People's Hospital (CN)
- West China Hospital of Sichuan University (CN)
- Cangzhou Central Hospital (CN)
- Nanfang Hospital (CN)
- First Hospital of Jilin University (CN)
- Ningxia Medical University (CN)
- General Hospital of Shenyang Military Region (CN)
- Ningxia Medical University General Hospital (CN)
- Tianjin Chest Hospital (CN)
- Beijing Tsinghua Chang Gung Hospital (CN)
- Shanxi Cardiovascular Hospital (CN)
Publication Details
- Journal
- BMC Cardiovascular Disorders
- Published
- 2025-12-30
- DOI
- https://doi.org/10.1186/s12872-025-05447-4
- Primary Topic
- Coronary Interventions and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 0.00