Improving radiation estimation from circular pool fires through field-of-view angle analysis

Thermal radiation is the dominant mode of heat transfer in large-scale pool fires, making accurate prediction of radiative heat flux essential for fire safety assessment and hazard analysis. Traditional approaches often rely on simplified representations, such as point-source models or the solid-flame model, in which the target is assumed to view only the “half-flame” surface in view factor calculations. This study develops a mathematical framework to quantify the influence of the field-of-view (FOV) angle on view factor estimation between a differential target and a circular pool fire, considering both cylindrical and conical flame geometries. The view factor integrals are derived using contour formulations and solved numerically with high accuracy. Results show that neglecting the actual FOV systematically underestimates the view factor, with deviations dependent on sensor height, flame radius, and target separation. For cylindrical flames, deviations can exceed 5% at near-field distances and large radii, while conical flames exhibit smaller deviations that remain within acceptable accuracy limits. Time-resolved analyses further demonstrate that temporal variations in flame height have little effect on the resulting view factor. Overall, these findings emphasize the importance of incorporating realistic FOV effects in radiation modeling, while also identifying conditions under which simplified assumptions remain sufficiently accurate. • Improved radiation modeling for cylindrical and conical pool fires. • Field-of-view approach enhances flame–target heat transfer prediction. • Corrects half-flame assumption used in pool fire radiation models. • Analytical formulation offers a low-cost substitute for Monte Carlo.

Authors

Institutions

Publication Details

Journal
International Journal of Heat and Mass Transfer
Published
2025-12-30
DOI
https://doi.org/10.1016/j.ijheatmasstransfer.2025.128312
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving radiation estimation from circular pool fires through field-of-view angle analysis

Peter A. Pinto, Mijail Littin
International Journal of Heat and Mass Transfer
Fire dynamics and safety research
article

Improving radiation estimation from circular pool fires through field-of-view angle analysis

Peter A. Pinto, Mijail Littin
article en

Abstract

Thermal radiation is the dominant mode of heat transfer in large-scale pool fires, making accurate prediction of radiative heat flux essential for fire safety assessment and hazard analysis. Traditional approaches often rely on simplified representations, such as point-source models or the solid-flame model, in which the target is assumed to view only the “half-flame” surface in view factor calculations. This study develops a mathematical framework to quantify the influence of the field-of-view (FOV) angle on view factor estimation between a differential target and a circular pool fire, considering both cylindrical and conical flame geometries. The view factor integrals are derived using contour formulations and solved numerically with high accuracy. Results show that neglecting the actual FOV systematically underestimates the view factor, with deviations dependent on sensor height, flame radius, and target separation. For cylindrical flames, deviations can exceed 5% at near-field distances and large radii, while conical flames exhibit smaller deviations that remain within acceptable accuracy limits. Time-resolved analyses further demonstrate that temporal variations in flame height have little effect on the resulting view factor. Overall, these findings emphasize the importance of incorporating realistic FOV effects in radiation modeling, while also identifying conditions under which simplified assumptions remain sufficiently accurate. • Improved radiation modeling for cylindrical and conical pool fires. • Field-of-view approach enhances flame–target heat transfer prediction. • Corrects half-flame assumption used in pool fire radiation models. • Analytical formulation offers a low-cost substitute for Monte Carlo.

International Journal of Heat and Mass TransferVol. 258
Worcester Polytechnic Institute (US), Centre National de la Recherche Scientifique (FR), Normandie Université (FR), Université de Rouen Normandie (FR), Institut National des Sciences Appliquées Rouen Normandie (FR)
Openalex Percentile: Top 35%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.