Tabletop pulsed x-ray ghost imaging with a single-pixel detector

Although "ghost" imaging has seen remarkable advances since it was first studied 30 years ago, there have been few studies on x-ray ghost imaging (XGI) due to technical difficulties. A chief potential advantage of XGI is that imaging can be achieved with much lower radiation intensity. However, in previous XGI experiments with continuous wave x-ray illumination, the total sampling time was actually quite long, leading to additional radiation dose accumulation. In this paper, we report a proof-of-concept experiment using a high-sensitivity single-pixel detector together with a simple tabletop x-ray source followed by an adjustable mechanical shutter, which could reduce the total exposure time to as little as 5 ms. Imaging was realized with a spatial resolution of 100 μm under a low radiation dose. The influence of x-ray tube current, sampling frequency, and exposure times on image quality was examined. Our experiment illustrates a practical method for low-radiation dose ghost imaging and provides valuable reference data for the future development of medical XGI cameras.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-12-01
DOI
https://doi.org/10.1063/5.0284934
Primary Topic
Random lasers and scattering media
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tabletop pulsed x-ray ghost imaging with a single-pixel detector

B. A. Shi, Yifei Li, Liming Chen, Ling-An Wu et al.
Review of Scientific Instruments
Random lasers and scattering media
article

Tabletop pulsed x-ray ghost imaging with a single-pixel detector

B. A. Shi, Yifei Li, Liming Chen, Ling-An Wu, X F Hu, Mingfei Li, Feng Jie, Jin-Guang Wang, Hui-Tong Zhai, Ming-Yang Zhu, Xin Lu, Hui Zeng
article en

Abstract

Although "ghost" imaging has seen remarkable advances since it was first studied 30 years ago, there have been few studies on x-ray ghost imaging (XGI) due to technical difficulties. A chief potential advantage of XGI is that imaging can be achieved with much lower radiation intensity. However, in previous XGI experiments with continuous wave x-ray illumination, the total sampling time was actually quite long, leading to additional radiation dose accumulation. In this paper, we report a proof-of-concept experiment using a high-sensitivity single-pixel detector together with a simple tabletop x-ray source followed by an adjustable mechanical shutter, which could reduce the total exposure time to as little as 5 ms. Imaging was realized with a spatial resolution of 100 μm under a low radiation dose. The influence of x-ray tube current, sampling frequency, and exposure times on image quality was examined. Our experiment illustrates a practical method for low-radiation dose ghost imaging and provides valuable reference data for the future development of medical XGI cameras.

Review of Scientific InstrumentsVol. 96(12)
Shanghai Jiao Tong University (CN), Physical Sciences (United States) (US), Songshan Lake Materials Laboratory (CN), Institute of Physics (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 31%
Random lasers and scattering media
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Tabletop pulsed x-ray ghost imaging with a single-pixel detector — B. A. Shi, Yifei Li, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS