A Proposal on Artificial Lighting Design in Offices Considering Visual Comfort and Energy Performance

Given the extensive working hours spent in offices today, ensuring visual comfort and energy efficiency in lighting design has becomea critical concern. This study aims to develop an approach to determine the effects of artificial lighting parameters on visual comfort and energy consumption in offices. For this purpose, office volumes of three different sizes and with varying surface reflection coefficient, assumed to be located in Trabzon, Turkey were first modeled using DIAlux evo simulation program. Variables related to artificial lighting design parameters were established, and calculations were perfomed within simulation program. W/lm/m2 values were calculated to evaluate the energy efficiency. The data obtained from this study were evaluated using regression analysis and inferential statistical analyses. Based on the findings, it is suggested that a lighting designer consider selecting an LED lamp, a surface mounted direct lighting luminarewitha microprismatic optic type to ensure the visual comfort and energy performance.

Authors

Institutions

Publication Details

Journal
Mimarlık Bilimleri ve Uygulamaları Dergisi (MBUD)
Published
2025-12-27
DOI
https://doi.org/10.30785/mbud.1676804
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Proposal on Artificial Lighting Design in Offices Considering Visual Comfort and Energy Performance

Mustafa Kavraz, Elif Öztürk Gül
Mimarlık Bilimleri ve Uygulamaları Dergisi (MBUD)
Building Energy and Comfort Optimization
article

A Proposal on Artificial Lighting Design in Offices Considering Visual Comfort and Energy Performance

Mustafa Kavraz, Elif Öztürk Gül
article en

Abstract

Given the extensive working hours spent in offices today, ensuring visual comfort and energy efficiency in lighting design has becomea critical concern. This study aims to develop an approach to determine the effects of artificial lighting parameters on visual comfort and energy consumption in offices. For this purpose, office volumes of three different sizes and with varying surface reflection coefficient, assumed to be located in Trabzon, Turkey were first modeled using DIAlux evo simulation program. Variables related to artificial lighting design parameters were established, and calculations were perfomed within simulation program. W/lm/m2 values were calculated to evaluate the energy efficiency. The data obtained from this study were evaluated using regression analysis and inferential statistical analyses. Based on the findings, it is suggested that a lighting designer consider selecting an LED lamp, a surface mounted direct lighting luminarewitha microprismatic optic type to ensure the visual comfort and energy performance.

Mimarlık Bilimleri ve Uygulamaları Dergisi (MBUD)Vol. 10(2)
Giresun University (TR), Karadeniz Technical University (TR)
Karadeniz Teknik Üniversitesi
Affordable and clean energy
Openalex Percentile: Top 37%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.