Hybrid Swarm Intelligence for FPGA-Based Noise Mitigation in Gradient-Sensitive MRI Systems

This research presents an advanced Magnetic Resonance Imaging (MRI) signal processing framework to address time-varying noise and environmental disturbances. A novel adaptive filtering mechanism is proposed to enhance noise mitigation while dynamically adjusting coefficients based on gradient field variations and magnetic coil responses. The core contribution lies in the development of a Modified Opposition-Based Artificial Ant Colony Optimization (MOACO) algorithm, marking the first application of an optimization algorithm tailored for MRI systems. The proposed method integrates swarm intelligence by combining opposition-based ant bee colony optimization, leveraging the cooperative behaviors of ants and bees to optimize the adaptive filter's weight estimation. The optimization process dynamically adjusts the step size, ensuring faster convergence and improved noise suppression. A Parallel Architecture Opposition-Based ABC algorithm is introduced for efficient hardware implementation. The effectiveness of the proposed solution is evaluated against conventional filtering methods, including Two-Dimensional LMS (TDLMS), Recursive Least Squares (RLS), and Adaptive Filtering Least Mean Error (AFLME). The algorithms are implemented on a Field-Programmable Gate Array (FPGA) platform, specifically the EP-FPGA-256C6 Cyclone, utilizing 65 nm and 90 nm CMOS technology nodes to ensure optimal power efficiency, reduced Look-Up Table (LUT) utilization, and minimal delay. Experimental results demonstrate that the MOACO-enhanced adaptive filtering framework significantly improves power efficiency, circuit performance, and noise reduction, leading to enhanced MRI image reconstruction and minimized motion artifacts. This study establishes a novel direction for integrating AI-driven optimization techniques with hardware-based MRI signal processing, paving the way for more efficient medical imaging systems.

Institutions

Publication Details

Journal
Tehnicki vjesnik - Technical Gazette
Published
2025-12-30
DOI
https://doi.org/10.17559/tv-20250103002232
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid Swarm Intelligence for FPGA-Based Noise Mitigation in Gradient-Sensitive MRI Systems

Tehnicki vjesnik - Technical Gazette
Advanced MRI Techniques and Applications
article

Hybrid Swarm Intelligence for FPGA-Based Noise Mitigation in Gradient-Sensitive MRI Systems

article en

Abstract

This research presents an advanced Magnetic Resonance Imaging (MRI) signal processing framework to address time-varying noise and environmental disturbances. A novel adaptive filtering mechanism is proposed to enhance noise mitigation while dynamically adjusting coefficients based on gradient field variations and magnetic coil responses. The core contribution lies in the development of a Modified Opposition-Based Artificial Ant Colony Optimization (MOACO) algorithm, marking the first application of an optimization algorithm tailored for MRI systems. The proposed method integrates swarm intelligence by combining opposition-based ant bee colony optimization, leveraging the cooperative behaviors of ants and bees to optimize the adaptive filter's weight estimation. The optimization process dynamically adjusts the step size, ensuring faster convergence and improved noise suppression. A Parallel Architecture Opposition-Based ABC algorithm is introduced for efficient hardware implementation. The effectiveness of the proposed solution is evaluated against conventional filtering methods, including Two-Dimensional LMS (TDLMS), Recursive Least Squares (RLS), and Adaptive Filtering Least Mean Error (AFLME). The algorithms are implemented on a Field-Programmable Gate Array (FPGA) platform, specifically the EP-FPGA-256C6 Cyclone, utilizing 65 nm and 90 nm CMOS technology nodes to ensure optimal power efficiency, reduced Look-Up Table (LUT) utilization, and minimal delay. Experimental results demonstrate that the MOACO-enhanced adaptive filtering framework significantly improves power efficiency, circuit performance, and noise reduction, leading to enhanced MRI image reconstruction and minimized motion artifacts. This study establishes a novel direction for integrating AI-driven optimization techniques with hardware-based MRI signal processing, paving the way for more efficient medical imaging systems.

Tehnicki vjesnik - Technical GazetteVol. 33(1)
Chennai Mathematical Institute (IN), Swami Vivekanand College of Pharmacy (IN), Social Service Sericulture Project Trust (IN), Open International University for Alternative Medicines (IN), E.G.S. Pillay Engineering College
Openalex Percentile: Top 30%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.