Challenges in validation studies of blood pressure measurement devices

Accurate blood pressure (BP) measurement is essential for effective health management. To ensure this, international standards for the validation of BP monitors have been established and revised over time, with ISO 81060-2:2018 being the most recent. While many studies have been published evaluating the accuracy of BP monitors based on this standard, we identified concerns regarding the reliability of some reported results and therefore conducted a comprehensive literature review. Using ISO 81060-2:2018 as the validation framework, we extracted relevant studies from PubMed and collected the SD values for criterion 1 to compare and analyze the reported measurement accuracy. While most SD values ranged from 5 to 8%, we identified six studies reporting values below 4%. On the basis of our experience, such low variability is highly implausible and raises questions about the credibility of these findings. Reports claiming exceptionally high measurement accuracy with unusually low SD values may lead to misconceptions and could potentially be misused for marketing purposes. Therefore, validation studies must be conducted in strict adherence to medical ethics. In addition, there is a need to raise awareness that the current international standards for BP monitor validation require further refinement.

Authors

Institutions

Publication Details

Journal
Blood Pressure Monitoring
Published
2025-12-23
DOI
https://doi.org/10.1097/mbp.0000000000000777
Primary Topic
Blood Pressure and Hypertension Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Challenges in validation studies of blood pressure measurement devices

K. Asayama, Hakuo Takahashi
Blood Pressure Monitoring
Blood Pressure and Hypertension Studies
article

Challenges in validation studies of blood pressure measurement devices

K. Asayama, Hakuo Takahashi
article en

Abstract

Accurate blood pressure (BP) measurement is essential for effective health management. To ensure this, international standards for the validation of BP monitors have been established and revised over time, with ISO 81060-2:2018 being the most recent. While many studies have been published evaluating the accuracy of BP monitors based on this standard, we identified concerns regarding the reliability of some reported results and therefore conducted a comprehensive literature review. Using ISO 81060-2:2018 as the validation framework, we extracted relevant studies from PubMed and collected the SD values for criterion 1 to compare and analyze the reported measurement accuracy. While most SD values ranged from 5 to 8%, we identified six studies reporting values below 4%. On the basis of our experience, such low variability is highly implausible and raises questions about the credibility of these findings. Reports claiming exceptionally high measurement accuracy with unusually low SD values may lead to misconceptions and could potentially be misused for marketing purposes. Therefore, validation studies must be conducted in strict adherence to medical ethics. In addition, there is a need to raise awareness that the current international standards for BP monitor validation require further refinement.

Blood Pressure MonitoringVol. 31(1)
Biwako Seikei Sport College (JP), Teikyo University (JP)
Partnerships for the goals
Openalex Percentile: Top 30%
Blood Pressure and Hypertension Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.