Improving the assessment of discharge fitness in an acute medical unit using wearable sensor data through machine learning

Assessing the physiological discharge fitness of acute medical unit (AMU) patients is feasible using machine learning with electronic medical record (EMR) data, including intermittently measured vital signs. Wearable sensor data including continuous monitored vital signs may improve this assessment. Therefore, the aim was to investigate the value of sensor data in assessing the physiological discharge fitness of AMU patients. EMR and sensor data of AMU patients ( n =145) who participated in a randomized controlled trial, conducted at a large teaching hospital in the Netherlands from December 2021 to October 2023, were used. EMR features were extracted from patient characteristics, vital signs, nursing assessments and laboratory results. Statistical features and neural features, derived from convolutional neural networks, were extracted from sensor data. Logistic regression (LR), random forest (RF) and extreme gradient boosting (XGB) were used as algorithms. For each, three models were optimized and assessed using nested cross validation: based on EMR, EMR with sensor, or only sensor data. The mean area under the receiver operator characteristic curve (AUROC) with 95%-confidence interval (95% CI) was used as the primary metric. For LR, RF and XGB, the mean AUROC (shown with 95% CI), obtained by models based on EMR with sensor data (0.73 (0.70 – 0.77), 0.73 (0.69 – 0.77) and 0.69 (0.64 – 0.73), respectively) was slightly better than or as good as obtained by models only considering EMR data (0.69 (0.65 – 0.73), 0.70 (0.66 – 0.73) and 0.69 (0.66 – 0.71), respectively) and as obtained by models only considering sensor data (0.70 (0.66 – 0.75), 0.71 (0.67 – 0.75) and 0.67 (0.63 – 0.71), respectively). Wearable sensor data could slightly improve the assessment of physiological discharge fitness of AMU patients compared to only using EMR data.

Authors

Institutions

Publication Details

Journal
Intelligent Medicine
Published
2025-12-01
DOI
https://doi.org/10.1016/j.imed.2025.12.010
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving the assessment of discharge fitness in an acute medical unit using wearable sensor data through machine learning

Mark Vincent Koning, Sandra F. Oude Wesselink, Bernard P. Veldkamp, Sjoerd H. Garssen et al.
Intelligent Medicine
Sepsis Diagnosis and Treatment
article

Improving the assessment of discharge fitness in an acute medical unit using wearable sensor data through machine learning

Mark Vincent Koning, Sandra F. Oude Wesselink, Bernard P. Veldkamp, Sjoerd H. Garssen, Carine J.M. Doggen, Maryam Amir Haeri
article en

Abstract

Assessing the physiological discharge fitness of acute medical unit (AMU) patients is feasible using machine learning with electronic medical record (EMR) data, including intermittently measured vital signs. Wearable sensor data including continuous monitored vital signs may improve this assessment. Therefore, the aim was to investigate the value of sensor data in assessing the physiological discharge fitness of AMU patients. EMR and sensor data of AMU patients ( n =145) who participated in a randomized controlled trial, conducted at a large teaching hospital in the Netherlands from December 2021 to October 2023, were used. EMR features were extracted from patient characteristics, vital signs, nursing assessments and laboratory results. Statistical features and neural features, derived from convolutional neural networks, were extracted from sensor data. Logistic regression (LR), random forest (RF) and extreme gradient boosting (XGB) were used as algorithms. For each, three models were optimized and assessed using nested cross validation: based on EMR, EMR with sensor, or only sensor data. The mean area under the receiver operator characteristic curve (AUROC) with 95%-confidence interval (95% CI) was used as the primary metric. For LR, RF and XGB, the mean AUROC (shown with 95% CI), obtained by models based on EMR with sensor data (0.73 (0.70 – 0.77), 0.73 (0.69 – 0.77) and 0.69 (0.64 – 0.73), respectively) was slightly better than or as good as obtained by models only considering EMR data (0.69 (0.65 – 0.73), 0.70 (0.66 – 0.73) and 0.69 (0.66 – 0.71), respectively) and as obtained by models only considering sensor data (0.70 (0.66 – 0.75), 0.71 (0.67 – 0.75) and 0.67 (0.63 – 0.71), respectively). Wearable sensor data could slightly improve the assessment of physiological discharge fitness of AMU patients compared to only using EMR data.

Intelligent Medicine
AOMB Intellectual Property (Netherlands) (NL), Rijnstate Hospital (NL), University of Twente (NL)
Openalex Percentile: Top 29%
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.