Fabrication and Characterization of a 10 × 10 cm Cold Atmospheric Pressure Plasma Array

We report the development of a large area cold atmospheric plasma (CAP) array. The device consists of a parallel stack of 43 linear-discharge plasma elements that create a 10 cm × 10 cm treatment area. The CAP device is fabricated using low temperature co-fired ceramic (LTCC) layers to create 10 cm long linear discharge channels (1.1 mm discharge gap) with embedded opposing silver metal electrodes. A 21 kHz AC voltage of 1.55 kVrms applied to the electrodes generates an Ar plasma between the plates, with the gas flow directing the reactive species toward the intended biological sample (bacteria biofilms, etc.) to affect the antimicrobial treatment. Internal ballast resistors (20 kΩ) were used on each side of the two electrode elements to improve discharge uniformity and to prevent large filamentary discharges. Typical element discharge currents were 3.5-4 mA with the total array current tested at 178 mA (rms) to provide optimal device uniformity at a 1.55 kV (rms), and an argon flow rate of 130 lpm. Further, the gas flow system was optimized to obtain a uniform plasma. Treatment of <i>Ps. fluorescence</i> bacterial biofilms on stainless steel coupons demonstrated a 91% decrease in colony forming units after 150 s of treatment with a 1.5 cm gap.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Plasma Science
Published
2025-12-30
DOI
https://doi.org/10.1109/tps.2025.3646554
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication and Characterization of a 10 × 10 cm Cold Atmospheric Pressure Plasma Array

Robert Russell Hay, Marcus Pearlman, Ranajoy Bhattacharya, Jim Browning et al.
IEEE Transactions on Plasma Science
Plasma Applications and Diagnostics
article

Fabrication and Characterization of a 10 × 10 cm Cold Atmospheric Pressure Plasma Array

Robert Russell Hay, Marcus Pearlman, Ranajoy Bhattacharya, Jim Browning, Nuha Akhtar, Dylan Brown, Kenneth A. Cornell, Daniel Miller, Sumona Islam
article en

Abstract

We report the development of a large area cold atmospheric plasma (CAP) array. The device consists of a parallel stack of 43 linear-discharge plasma elements that create a 10 cm × 10 cm treatment area. The CAP device is fabricated using low temperature co-fired ceramic (LTCC) layers to create 10 cm long linear discharge channels (1.1 mm discharge gap) with embedded opposing silver metal electrodes. A 21 kHz AC voltage of 1.55 kVrms applied to the electrodes generates an Ar plasma between the plates, with the gas flow directing the reactive species toward the intended biological sample (bacteria biofilms, etc.) to affect the antimicrobial treatment. Internal ballast resistors (20 kΩ) were used on each side of the two electrode elements to improve discharge uniformity and to prevent large filamentary discharges. Typical element discharge currents were 3.5-4 mA with the total array current tested at 178 mA (rms) to provide optimal device uniformity at a 1.55 kV (rms), and an argon flow rate of 130 lpm. Further, the gas flow system was optimized to obtain a uniform plasma. Treatment of <i>Ps. fluorescence</i> bacterial biofilms on stainless steel coupons demonstrated a 91% decrease in colony forming units after 150 s of treatment with a 1.5 cm gap.

IEEE Transactions on Plasma ScienceVol. 54(2)
Boise State University (US)
Openalex Percentile: Top 30%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.