Impact of different cross.section designs of rotary instruments on smear layer removal, cyclic and torsional fatigue resistance: In vitro study

Introduction: In endodontics, mechanized nickel–titanium (NiTi) instruments are widely adopted for both initial treatments and retreatment because of their flexibility and minimal impact on root canal trajectory. This study aimed to assess the effect of four rotary NiTi systems on the quantity of smear layer remaining on dentin walls after instrumentation and to compare their resistance to cyclic and torsional fatigue. Materials and Methods: Forty mandibular incisors ( n = 10) were divided into four groups according to the file used for instrumentation: spin, S2, rotate, and platinum V.EU rotary files. Dentin wall evaluation for smear layer was performed through scanning electron microscopy. For mechanical tests, 80 instruments were used in total, with 40 instruments ( n = 10 per group) undergoing cyclic fatigue analysis using an artificial canal apparatus and another 40 instruments ( n = 10 per group) undergoing torsional fatigue analysis using a custom-designed torsion machine. All instruments had a 0.25 mm diameter and underwent cyclic and torsional fatigue analysis. Statistical analysis was conducted at a 5% significance level. Results: Intergroup comparisons showed a comparable percentage of smear layer on dentin walls ( P > 0.05). Cyclic fatigue tests indicated that spin and S2 instruments possessed the highest resistance ( P < 0.05). The rotate system demonstrated the greatest angular deflection and the lowest torque ( P < 0.05). Conclusion: All tested rotary systems yielded similar smear layer accumulation but exhibited varying cyclic and torsional properties.

Authors

Institutions

Publication Details

Journal
Saudi Endodontic Journal
Published
2025-12-30
DOI
https://doi.org/10.4103/sej.sej_160_25
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of different cross.section designs of rotary instruments on smear layer removal, cyclic and torsional fatigue resistance: In vitro study

Pablo A. Amoroso‐Silva, Guilherme Ferreira da Silva, João Pedro Tadano, Ana Grasiela Limoeiro et al.
Saudi Endodontic Journal
Endodontics and Root Canal Treatments
article

Impact of different cross.section designs of rotary instruments on smear layer removal, cyclic and torsional fatigue resistance: In vitro study

Pablo A. Amoroso‐Silva, Guilherme Ferreira da Silva, João Pedro Tadano, Ana Grasiela Limoeiro, Murilo Priori Alcalde, Rodrigo Riccci Vivan, Raimundo Sales Oliveira-Neto, Paula Tereza Galvão, Marco Antônio Duarte
article en

Abstract

Introduction: In endodontics, mechanized nickel–titanium (NiTi) instruments are widely adopted for both initial treatments and retreatment because of their flexibility and minimal impact on root canal trajectory. This study aimed to assess the effect of four rotary NiTi systems on the quantity of smear layer remaining on dentin walls after instrumentation and to compare their resistance to cyclic and torsional fatigue. Materials and Methods: Forty mandibular incisors ( n = 10) were divided into four groups according to the file used for instrumentation: spin, S2, rotate, and platinum V.EU rotary files. Dentin wall evaluation for smear layer was performed through scanning electron microscopy. For mechanical tests, 80 instruments were used in total, with 40 instruments ( n = 10 per group) undergoing cyclic fatigue analysis using an artificial canal apparatus and another 40 instruments ( n = 10 per group) undergoing torsional fatigue analysis using a custom-designed torsion machine. All instruments had a 0.25 mm diameter and underwent cyclic and torsional fatigue analysis. Statistical analysis was conducted at a 5% significance level. Results: Intergroup comparisons showed a comparable percentage of smear layer on dentin walls ( P > 0.05). Cyclic fatigue tests indicated that spin and S2 instruments possessed the highest resistance ( P < 0.05). The rotate system demonstrated the greatest angular deflection and the lowest torque ( P < 0.05). Conclusion: All tested rotary systems yielded similar smear layer accumulation but exhibited varying cyclic and torsional properties.

Saudi Endodontic JournalVol. 16(1)
Universidade Estadual de Londrina (BR), Universidade Federal da Grande Dourados (BR), University of Dental Medicine (MM)
Openalex Percentile: Top 28%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.