Efficacy and Safety of Lag Screw Fixation in Unstable Hangman’s Fractures: A Systematic Review and Meta-analysis

<sec><title>Objectives</title> Hangman’s fracture, caused by high-energy hyperextension with axial loading trauma, remains challenging to manage. Unstable types (IIa and III) can be treated by a variety of surgical options. Lag-screw fixation has recently gained attention owing to its compatibility with navigation, minimally invasive instrumentation, and lower surgical morbidity. </sec><sec><title>Methods</title> A systematic review and meta-analysis of surgical efficacy and safety of lag screw fixation was undertaken. Nine studies, which included a total of 128 patients, assessed outcomes of lag screw fixation, including neck range of motion, intervertebral angle (C2–C3), postoperative pain (visual analog scale), intraoperative parameters, and complications. </sec><sec><title>Results</title> Significant improvements were observed in pooled range of motion (extension: 6.28°, flexion: 5.13°) and correction of the C2 to C3 angle by −3.54° (<italic>P</italic> < 0.001) vs baseline. Pain decreased across early and late timepoints, although heterogeneity reflects variable follow-up and unreported analgesic/analgesia protocols. Reported complications were low in the included series. </sec><sec><title>Conclusion</title> C2 transpedicular lag-screw fixation restores alignment and preserves motion with low reported complications in available case series. Larger comparative trials are needed to define its role relative to fusion techniques. </sec><sec><title>Clinical Relevance</title> Direct osteosynthesis of unstable hangman’s fractures via lag-screw fixation offers a viable motion-preserving alternative to C2–C3 fusion. By avoiding fusion, this technique maintains physiological cervical biomechanics and reduces the risk of adjacent segment disease. However, clinicians must carefully weigh these benefits against the technical demands of screw placement and the current lack of high-level comparative evidence. </sec><sec><title>Level of Evidence</title> 4. </sec>

Authors

Institutions

Publication Details

Journal
The International Journal of Spine Surgery
Published
2025-12-01
DOI
https://doi.org/10.14444/8832
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy and Safety of Lag Screw Fixation in Unstable Hangman’s Fractures: A Systematic Review and Meta-analysis

Elham Rahmanipour, Khushal Gupta, Mohammad Ali Abouei Mehrizi, Mohammad Amin Habibi et al.
The International Journal of Spine Surgery
Orthopedic Surgery and Rehabilitation
article

Efficacy and Safety of Lag Screw Fixation in Unstable Hangman’s Fractures: A Systematic Review and Meta-analysis

Elham Rahmanipour, Khushal Gupta, Mohammad Ali Abouei Mehrizi, Mohammad Amin Habibi, Mahyar Daskareh, Saeid Esmaeilian, Mohammad Sina Mirjani, Bardia Hajikarimloo, Michael Karsy, Golnaz Golrokhian Sani, Mohammad Ghorbani, Shaghayegh Karami, Seyed Ali Moshtaghioon
article en

Abstract

<sec><title>Objectives</title> Hangman’s fracture, caused by high-energy hyperextension with axial loading trauma, remains challenging to manage. Unstable types (IIa and III) can be treated by a variety of surgical options. Lag-screw fixation has recently gained attention owing to its compatibility with navigation, minimally invasive instrumentation, and lower surgical morbidity. </sec><sec><title>Methods</title> A systematic review and meta-analysis of surgical efficacy and safety of lag screw fixation was undertaken. Nine studies, which included a total of 128 patients, assessed outcomes of lag screw fixation, including neck range of motion, intervertebral angle (C2–C3), postoperative pain (visual analog scale), intraoperative parameters, and complications. </sec><sec><title>Results</title> Significant improvements were observed in pooled range of motion (extension: 6.28°, flexion: 5.13°) and correction of the C2 to C3 angle by −3.54° (<italic>P</italic> < 0.001) vs baseline. Pain decreased across early and late timepoints, although heterogeneity reflects variable follow-up and unreported analgesic/analgesia protocols. Reported complications were low in the included series. </sec><sec><title>Conclusion</title> C2 transpedicular lag-screw fixation restores alignment and preserves motion with low reported complications in available case series. Larger comparative trials are needed to define its role relative to fusion techniques. </sec><sec><title>Clinical Relevance</title> Direct osteosynthesis of unstable hangman’s fractures via lag-screw fixation offers a viable motion-preserving alternative to C2–C3 fusion. By avoiding fusion, this technique maintains physiological cervical biomechanics and reduces the risk of adjacent segment disease. However, clinicians must carefully weigh these benefits against the technical demands of screw placement and the current lack of high-level comparative evidence. </sec><sec><title>Level of Evidence</title> 4. </sec>

The International Journal of Spine SurgeryVol. 19(6)
Mashhad University of Medical Sciences (IR), Shiraz University of Medical Sciences (IR), University of Michigan (US), Pt. Jawahar Lal Nehru Memorial Medical College (IN), Shariati Hospital (IR), University of Virginia (US), Qom University of Medical Science and Health Services (IR), Tehran University of Medical Sciences (IR), University of Pennsylvania (US)
Openalex Percentile: Top 25%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.