Tracking Radial Artery Dynamics Using Brightness-Mode Ultrasound and Video Analysis

Cardiovascular disease is an important concern and the evaluation of vascular health is a key element for early detection. However, continuous non-invasive measurement of vascular health is limited to clinical settings while wearable health sensing devices are lacking vascular health detection. To achieve such wearable continuous cardiovascular health measurement, better understanding about physical properties of the vascular system are needed. Towards the development of wearable continuous cardiovascular health monitoring, we developed, verified, and validated an algorithm to estimate the dynamic radius of the radial artery and estimated the arterial pulsation from brightness-mode ultrasound imaging. The algorithm was implemented using Python and MATLAB®. The algorithm was tested using a simulation environment, as well as ultrasound imaging together with continuous non-invasive arterial pressure monitoring from participants. The radial artery size and distance from surface measured was >90% accurate. We report an informative summary from 6 participants. The radial artery radius change over time was used to estimate heart-beat rate, and showed reasonable accuracy for 5 out of 6 participants.

Authors

Institutions

Publication Details

Published
2025-10-12
DOI
https://doi.org/10.1145/3714394.3755877
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tracking Radial Artery Dynamics Using Brightness-Mode Ultrasound and Video Analysis

Tuukka Panula, Craig S. Carlson, T. Kärkkäinen, Stephan Sigg et al.
Non-Invasive Vital Sign Monitoring
article

Tracking Radial Artery Dynamics Using Brightness-Mode Ultrasound and Video Analysis

Tuukka Panula, Craig S. Carlson, T. Kärkkäinen, Stephan Sigg, Ivan Vujaklija, Nima Bahmani, Janne Kantola, Oula Aarela, Otso Häkkänen, Venla Turakainen, Viktor Nässi
article en

Abstract

Cardiovascular disease is an important concern and the evaluation of vascular health is a key element for early detection. However, continuous non-invasive measurement of vascular health is limited to clinical settings while wearable health sensing devices are lacking vascular health detection. To achieve such wearable continuous cardiovascular health measurement, better understanding about physical properties of the vascular system are needed. Towards the development of wearable continuous cardiovascular health monitoring, we developed, verified, and validated an algorithm to estimate the dynamic radius of the radial artery and estimated the arterial pulsation from brightness-mode ultrasound imaging. The algorithm was implemented using Python and MATLAB®. The algorithm was tested using a simulation environment, as well as ultrasound imaging together with continuous non-invasive arterial pressure monitoring from participants. The radial artery size and distance from surface measured was >90% accurate. We report an informative summary from 6 participants. The radial artery radius change over time was used to estimate heart-beat rate, and showed reasonable accuracy for 5 out of 6 participants.

University of Turku (FI), Aalto University (FI)
Good health and well-being
Openalex Percentile: Top 41%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Tracking Radial Artery Dynamics Using Brightness-Mode Ultrasound and Video Analysis — Tuukka Panula, Craig S. Carlson, et al. · (2025) | TGRS Research Map | TGRS