A Hybrid Dynamic Model for the Thermal Compressor Heat Pump and Validation with Experimental Data

Thermally driven heat pumps primarily use thermal energy to drive a compression cycle. The thermal energy can be waste heat, natural-gas combustion, or solar, helping increase efficiency and reduce greenhouse-gas emissions. We study a thermal compressor heat pump (TCHP) in which Stirling-type thermal compressors (TCs) are heat-driven rather than electrically driven, delivering a nominal heat capacity of 8 kW with CO2 as the refrigerant. Unlike most existing dynamic models of CO2 cycles, which focus on electrically driven or single-stage systems, this work targets a heat-driven multi-stage configuration and includes transient validation. Like any vapor compression cycle (VCC), a TCHP requires a dynamic model for control and optimization; its predictive reliability must be validated on experimental data. We therefore describe the test bench and performance expressions, collect steady-state and transient datasets, and derive a hybrid dynamic model: finite-volume (FV) differential equations for slow components and quasi-static submodels (linear regressions and correlations) for fast elements. The contribution of this work is the development and experimental validation of a hybrid FV model for a multi-stage heat-driven CO2 TCHP. Validation against both steady-state and transient datasets shows good agreement. On 15 steady-state operating points, the model reproduces pressures within ∼1 bar mean absolute error (MAE) and system-level performance (total recovered heat, COPth) within ∼6% mean absolute percentage error (MAPE), with R2≳0.8; component heat-rate predictions are within ∼20% MAPE. Under transient step tests on expansion valve openings and burner fan speed, the thermal COP and total recovered heat track within 4% MAPE (up to R2=0.96), pressures within 1.5 bar MAE, and the evaporator heat rate within 14–22% MAPE.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-12-27
DOI
https://doi.org/10.3390/en19010159
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Hybrid Dynamic Model for the Thermal Compressor Heat Pump and Validation with Experimental Data

Pascal Dufour, V. Lemort, Madiha Nadri, Ali Salame
Energies
Refrigeration and Air Conditioning Technologies
article

A Hybrid Dynamic Model for the Thermal Compressor Heat Pump and Validation with Experimental Data

Pascal Dufour, V. Lemort, Madiha Nadri, Ali Salame
article en

Abstract

Thermally driven heat pumps primarily use thermal energy to drive a compression cycle. The thermal energy can be waste heat, natural-gas combustion, or solar, helping increase efficiency and reduce greenhouse-gas emissions. We study a thermal compressor heat pump (TCHP) in which Stirling-type thermal compressors (TCs) are heat-driven rather than electrically driven, delivering a nominal heat capacity of 8 kW with CO2 as the refrigerant. Unlike most existing dynamic models of CO2 cycles, which focus on electrically driven or single-stage systems, this work targets a heat-driven multi-stage configuration and includes transient validation. Like any vapor compression cycle (VCC), a TCHP requires a dynamic model for control and optimization; its predictive reliability must be validated on experimental data. We therefore describe the test bench and performance expressions, collect steady-state and transient datasets, and derive a hybrid dynamic model: finite-volume (FV) differential equations for slow components and quasi-static submodels (linear regressions and correlations) for fast elements. The contribution of this work is the development and experimental validation of a hybrid FV model for a multi-stage heat-driven CO2 TCHP. Validation against both steady-state and transient datasets shows good agreement. On 15 steady-state operating points, the model reproduces pressures within ∼1 bar mean absolute error (MAE) and system-level performance (total recovered heat, COPth) within ∼6% mean absolute percentage error (MAPE), with R2≳0.8; component heat-rate predictions are within ∼20% MAPE. Under transient step tests on expansion valve openings and burner fan speed, the thermal COP and total recovered heat track within 4% MAPE (up to R2=0.96), pressures within 1.5 bar MAE, and the evaporator heat rate within 14–22% MAPE.

EnergiesVol. 19(1)
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), University of Liège (BE), Laboratoire d'Automatique, de Génie des Procédés et de Génie Pharmaceutique (FR)
Association Nationale de la Recherche et de la Technologie
Affordable and clean energy
Openalex Percentile: Top 44%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.