A Modified Oedometer with Control Suction and Temperature

Abstract Pressure plate devices have been developed to investigate the hydromechanical behaviour of unsaturated soils using the axis translation technique (ATT). Despite the progress in experimental methods, there are still some problems concerning the ATT application, e.g., the evaporation and condensation of water on cell walls. This investigation discusses a fabricated device-dissolving condensation problem linked to the ATT. A modified suction temperature-controlled oedometer was developed and successfully employed to perform various experiments on unsaturated soils by controlling the vertical net stress, suction, and temperature simultaneously as well as minimizing any problems related to water condensation. The heating system employed for the modified device significantly reduced the water volume errors involving condensation, which varied from 0 to 1.12% in the soil-water characteristic curve (SWCC) test. In addition, the established SWCC of residual granite soil using the modified oedometer was verified by the pressure plate technique.

Authors

Institutions

Publication Details

Journal
Slovak Journal of Civil Engineering
Published
2025-12-01
DOI
https://doi.org/10.2478/sjce-2025-0023
Primary Topic
Soil and Unsaturated Flow
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Modified Oedometer with Control Suction and Temperature

Mehrdad Kholghifard, Kamarudin Ahmad
Slovak Journal of Civil Engineering
Soil and Unsaturated Flow
article

A Modified Oedometer with Control Suction and Temperature

Mehrdad Kholghifard, Kamarudin Ahmad
article en

Abstract

Abstract Pressure plate devices have been developed to investigate the hydromechanical behaviour of unsaturated soils using the axis translation technique (ATT). Despite the progress in experimental methods, there are still some problems concerning the ATT application, e.g., the evaporation and condensation of water on cell walls. This investigation discusses a fabricated device-dissolving condensation problem linked to the ATT. A modified suction temperature-controlled oedometer was developed and successfully employed to perform various experiments on unsaturated soils by controlling the vertical net stress, suction, and temperature simultaneously as well as minimizing any problems related to water condensation. The heating system employed for the modified device significantly reduced the water volume errors involving condensation, which varied from 0 to 1.12% in the soil-water characteristic curve (SWCC) test. In addition, the established SWCC of residual granite soil using the modified oedometer was verified by the pressure plate technique.

Slovak Journal of Civil EngineeringVol. 33(4)
Islamic Azad University Yasuj (IR), University of Technology Malaysia (MY)
Clean water and sanitation
Openalex Percentile: Top 36%
Soil and Unsaturated Flow
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.