New insights into HCl-induced low-temperature corrosion in biomass- and waste-fired boilers

This study investigates the risk of low-temperature corrosion on carbon steel tube surfaces located at the clean side of the flue gas channel downstream of a selective catalytic reduction (SCR) unit in a full-scale bubbling fluidized bed (BFB) boiler, where the HCl(g) concentration is typically very low (<5 ppm v ). Short- and long-term corrosion probe measurements, along with online deposit monitoring, were carried out in the flue gas channel to determine the causes of corrosion and establish safe material temperatures. To further investigate the results, laboratory tests were conducted in a quartz-tube furnace under simulated flue gas conditions. The results demonstrated that corrosion rates increased once the material surface temperature fell below 90 °C, with particularly severe attack evident at 80 and 70 °C. Notably, a considerable amount of chlorine was present in the corrosion products, indicating a high risk of chlorine-induced corrosion at cold-end surfaces, even at very low HCl(g) concentrations. Two potential corrosion mechanisms were identified, namely the absorption of HCl(g) into surface-adsorbed water monolayers above the water dew point, and the presence of corrosive NH 4 Cl(s,aq) on tube surfaces. HCl-induced corrosion was found to be the most likely mechanism. According to this mechanism, corrosion can occur even without bulk water condensation, and it depends on the local relative humidity (RH) at the steel surface. The findings collectively suggest that carbon steel surfaces on the clean side of the flue gas path should be maintained above approximately 90 °C (with an appropriate safety margin, depending on flue gas H 2 O(g) concentration) to mitigate the observed HCl-induced corrosion. A similar corrosion mechanism may also affect the dirty side of the flue gas path at similarly low temperatures. • In BFB boilers, cold-end surfaces are at risk of Cl-induced corrosion below ≈90 °C. • Corrosion is mainly due to HCl(g) adsorption into surface-adsorbed water monolayers. • Even <5 ppm v HCl(g) can cause corrosion on carbon steel under flue gas conditions.

Authors

Institutions

Publication Details

Journal
Corrosion Science
Published
2025-12-27
DOI
https://doi.org/10.1016/j.corsci.2025.113587
Citations
1
Primary Topic
Chemical Looping and Thermochemical Processes
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New insights into HCl-induced low-temperature corrosion in biomass- and waste-fired boilers

Emil Vainio, Hanna Kinnunen, Alessandro Ruozzi, Farzad Jafarihonar et al.
1 citations
Corrosion Science
Chemical Looping and Thermochemical Processes
0.67
article

New insights into HCl-induced low-temperature corrosion in biomass- and waste-fired boilers

Emil Vainio, Hanna Kinnunen, Alessandro Ruozzi, Farzad Jafarihonar, Leena Hupa
article en
1 citations

Abstract

This study investigates the risk of low-temperature corrosion on carbon steel tube surfaces located at the clean side of the flue gas channel downstream of a selective catalytic reduction (SCR) unit in a full-scale bubbling fluidized bed (BFB) boiler, where the HCl(g) concentration is typically very low (<5 ppm v ). Short- and long-term corrosion probe measurements, along with online deposit monitoring, were carried out in the flue gas channel to determine the causes of corrosion and establish safe material temperatures. To further investigate the results, laboratory tests were conducted in a quartz-tube furnace under simulated flue gas conditions. The results demonstrated that corrosion rates increased once the material surface temperature fell below 90 °C, with particularly severe attack evident at 80 and 70 °C. Notably, a considerable amount of chlorine was present in the corrosion products, indicating a high risk of chlorine-induced corrosion at cold-end surfaces, even at very low HCl(g) concentrations. Two potential corrosion mechanisms were identified, namely the absorption of HCl(g) into surface-adsorbed water monolayers above the water dew point, and the presence of corrosive NH 4 Cl(s,aq) on tube surfaces. HCl-induced corrosion was found to be the most likely mechanism. According to this mechanism, corrosion can occur even without bulk water condensation, and it depends on the local relative humidity (RH) at the steel surface. The findings collectively suggest that carbon steel surfaces on the clean side of the flue gas path should be maintained above approximately 90 °C (with an appropriate safety margin, depending on flue gas H 2 O(g) concentration) to mitigate the observed HCl-induced corrosion. A similar corrosion mechanism may also affect the dirty side of the flue gas path at similarly low temperatures. • In BFB boilers, cold-end surfaces are at risk of Cl-induced corrosion below ≈90 °C. • Corrosion is mainly due to HCl(g) adsorption into surface-adsorbed water monolayers. • Even <5 ppm v HCl(g) can cause corrosion on carbon steel under flue gas conditions.

Corrosion ScienceVol. 261
Åbo Akademi University (FI)
Openalex Percentile: Top 23%
Chemical Looping and Thermochemical Processes
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.