Measurement of knee joint space width with bi-planar radiography

The objective of this study was to identify whether the joint space width (JSW) of the knee, measured by bi-planar imaging, is reproducible compared to the clinical reference radiography. Our cross-sectional study design included a cohort of uninjured individuals (<i>N</i> = 30, 26.7 ± 5.1 yr) who underwent scanning to determine the short-term precision of the technique, involving repeat scans by bi-planar radiograph. Additionally, repeat conventional tunnel view knee radiographs were used as a comparator. The minimum apparent tibiofemoral JSW was collected for each leg side and compartment for both modalities. The root-mean-square coefficient of variation (RMSCV) and least significant change (LSC) for bi-planar scans (RMSCV = 6.46%, LSC = 1.07 mm) were comparable to conventional radiography (CR) (RMSCV = 7.66%, LSC = 1.15 mm). There was a bias for greater JSW by bi-planar radiography than CR (9.0%, <i>p</i> < .01), particularly for the forward unloaded left leg lateral (15.5%) and medial (17.6%) compartments. In conclusion, we found that JSW measurements from bi-planar scanners are reproducible and comparable to CR. While radiography remains accessible clinically, accurate and precise JSW by bi-planar scanners is feasible provided knee position and alignment are controlled.

Authors

Institutions

Publication Details

Journal
JBMR Plus
Published
2025-12-23
DOI
https://doi.org/10.1093/jbmrpl/ziaf196
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of knee joint space width with bi-planar radiography

R. L. Walker, Isabella Derij Vandergaag, Steven K Boyd
JBMR Plus
Total Knee Arthroplasty Outcomes
article

Measurement of knee joint space width with bi-planar radiography

R. L. Walker, Isabella Derij Vandergaag, Steven K Boyd
article en

Abstract

The objective of this study was to identify whether the joint space width (JSW) of the knee, measured by bi-planar imaging, is reproducible compared to the clinical reference radiography. Our cross-sectional study design included a cohort of uninjured individuals (<i>N</i> = 30, 26.7 ± 5.1 yr) who underwent scanning to determine the short-term precision of the technique, involving repeat scans by bi-planar radiograph. Additionally, repeat conventional tunnel view knee radiographs were used as a comparator. The minimum apparent tibiofemoral JSW was collected for each leg side and compartment for both modalities. The root-mean-square coefficient of variation (RMSCV) and least significant change (LSC) for bi-planar scans (RMSCV = 6.46%, LSC = 1.07 mm) were comparable to conventional radiography (CR) (RMSCV = 7.66%, LSC = 1.15 mm). There was a bias for greater JSW by bi-planar radiography than CR (9.0%, <i>p</i> < .01), particularly for the forward unloaded left leg lateral (15.5%) and medial (17.6%) compartments. In conclusion, we found that JSW measurements from bi-planar scanners are reproducible and comparable to CR. While radiography remains accessible clinically, accurate and precise JSW by bi-planar scanners is feasible provided knee position and alignment are controlled.

JBMR PlusVol. 10(2)
University of Calgary (CA), Alberta Bone and Joint Health Institute (CA)
Canadian Institutes of Health Research
Openalex Percentile: Top 26%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.