Paper-based graphene bioelectrode enabling third-generation fructose dehydrogenase sensing of inulin

Here, the first paper-based direct electron-transfer enzymatic biosensor is presented. This is the first biosensor designed to enable simple detection of inulin in biological fluids, serving as an exogenous marker for estimating glomerular filtration rate (GFR). The biosensor relies on a laser-induced graphene (LIG) paper-based sensor integrating Fructose Dehydrogenase (FDH). This enzyme was incorporated into paper for the first time in this work and demonstrated direct electron transfer (DET) capability. Various cellulosic substrates were evaluated as biosensor supports, and a tree-free bamboo-derived paper (FB) was selected for its ability to accommodate both LIG as the transducer film and FDH as the bioreceptor. The FB-LIG, which yielded the highest bioelectrocatalytic response, was employed to determine inulin in human urine and serum in the context of GFR studies. The FB-LIG biosensor was selective, and via matrix-matched calibration was used to determine inulin in samples, obtaining useful dose-response linearity (urine: 1.6-22.7 mg L<sup>-1</sup>; serum: 4.6-11.4 mg L<sup>-1</sup>) and the needed sensitivity (LOD: urine = 0.3 mg L<sup>-1</sup>, serum = 1.0 mg L<sup>-1</sup>), together with high reproducibility (RSD ≤2.0 %, n = 3). The complete inulin analysis takes less than 10 min and includes a rapid hydrolysis step followed by direct biosensor measurement. The FB-LIG biosensor reliability was demonstrated by measuring inulin in real urine and serum samples at clinically relevant levels, achieving satisfactory recoveries (90-111 %; RSD ≤7.9 %, n = 3). Here, for the first time, a sustainable substrate enabled the development of a paper-based third-generation biosensor, demonstrating the potential of LIG on paper for bioelectrocatalysis.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2025-12-27
DOI
https://doi.org/10.1016/j.bios.2025.118347
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Paper-based graphene bioelectrode enabling third-generation fructose dehydrogenase sensing of inulin

Luisa Torsi, V. Notarstefano, D. Compagnone, Y. Suzuki et al.
Biosensors and Bioelectronics
Electrochemical sensors and biosensors
article

Paper-based graphene bioelectrode enabling third-generation fructose dehydrogenase sensing of inulin

Luisa Torsi, V. Notarstefano, D. Compagnone, Y. Suzuki, F. Silveri, I.V. Di Cristoforo, D. Paolini, E. Fukawa, K. Sowa, F. Della Pelle, A. Scroccarello, P. Bollella
article en

Abstract

Here, the first paper-based direct electron-transfer enzymatic biosensor is presented. This is the first biosensor designed to enable simple detection of inulin in biological fluids, serving as an exogenous marker for estimating glomerular filtration rate (GFR). The biosensor relies on a laser-induced graphene (LIG) paper-based sensor integrating Fructose Dehydrogenase (FDH). This enzyme was incorporated into paper for the first time in this work and demonstrated direct electron transfer (DET) capability. Various cellulosic substrates were evaluated as biosensor supports, and a tree-free bamboo-derived paper (FB) was selected for its ability to accommodate both LIG as the transducer film and FDH as the bioreceptor. The FB-LIG, which yielded the highest bioelectrocatalytic response, was employed to determine inulin in human urine and serum in the context of GFR studies. The FB-LIG biosensor was selective, and via matrix-matched calibration was used to determine inulin in samples, obtaining useful dose-response linearity (urine: 1.6-22.7 mg L<sup>-1</sup>; serum: 4.6-11.4 mg L<sup>-1</sup>) and the needed sensitivity (LOD: urine = 0.3 mg L<sup>-1</sup>, serum = 1.0 mg L<sup>-1</sup>), together with high reproducibility (RSD ≤2.0 %, n = 3). The complete inulin analysis takes less than 10 min and includes a rapid hydrolysis step followed by direct biosensor measurement. The FB-LIG biosensor reliability was demonstrated by measuring inulin in real urine and serum samples at clinically relevant levels, achieving satisfactory recoveries (90-111 %; RSD ≤7.9 %, n = 3). Here, for the first time, a sustainable substrate enabled the development of a paper-based third-generation biosensor, demonstrating the potential of LIG on paper for bioelectrocatalysis.

Biosensors and BioelectronicsVol. 297
University of Teramo (IT), Kyoto University (JP), University of Bari Aldo Moro (IT)
Responsible consumption and production
Openalex Percentile: Top 42%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.