Reproducible Capillary Electrophoresis–Mass Spectrometry–Based Top‐Down Proteomics of Complex Proteomes Enabled by an Advanced Cationic Polymer Coating

Capillary zone electrophoresis-mass spectrometry (CZE-MS) has become a powerful tool for top-down proteomics (TDP). Capillaries are commonly coated with neutral or cationic polymers to reduce protein adsorption in CZE-MS. We recently introduced a cationic polymer coating [poly(acrylamide-co-(3-acrylamidopropyl) trimethylammonium chloride (PAMAPTAC)] to CZE-MS-based TDP. Here, we further improved the coating procedure to enhance the ease and repeatability of the cationic coating preparation by employing 2,2'-azobisisobutyronitrile (AIBN) as the radical initiator and methanol as the solvent. The new coating method not only simplifies the coating process but is also user-friendly. Different laboratory members were able to reproduce this type of cationic coating with consistent CZE-MS performance. We evaluated the performance of CZE-MS with the cationic coating in analyzing various complex biological samples (nanoparticle protein corona, histone, and an Escherichia coli cell lysate) and assessed its long-term reproducibility with an E. coli cell lysate for 35 runs (over 40 h) of continuous measurement. The CZE-MS system produced reproducible measurements for all the samples regarding separation profiles, proteoform migration time (MT), and proteoform intensity. For example, the system enabled the detection of large proteoforms (26-35 kDa) from an E. coli sample with consistent MT, relative standard deviations (RSDs) <7% without MT correction and 2.1% after MT alignment. We expect that the APTAC coating will further advance CZE-MS-based TDP for broad and large-scale applications.

Authors

Institutions

Publication Details

Journal
Journal of Mass Spectrometry
Published
2025-12-26
DOI
https://doi.org/10.1002/jms.70005
Citations
1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducible Capillary Electrophoresis–Mass Spectrometry–Based Top‐Down Proteomics of Complex Proteomes Enabled by an Advanced Cationic Polymer Coating

Yifan Yue, Qi Wang, Ao Zhang, Guijie Zhu et al.
1 citations
Journal of Mass Spectrometry
Mass Spectrometry Techniques and Applications
0.76
article

Reproducible Capillary Electrophoresis–Mass Spectrometry–Based Top‐Down Proteomics of Complex Proteomes Enabled by an Advanced Cationic Polymer Coating

Yifan Yue, Qi Wang, Ao Zhang, Guijie Zhu, Fei Fang, Liangliang Sun, Guangyao Gao
article en
1 citations

Abstract

Capillary zone electrophoresis-mass spectrometry (CZE-MS) has become a powerful tool for top-down proteomics (TDP). Capillaries are commonly coated with neutral or cationic polymers to reduce protein adsorption in CZE-MS. We recently introduced a cationic polymer coating [poly(acrylamide-co-(3-acrylamidopropyl) trimethylammonium chloride (PAMAPTAC)] to CZE-MS-based TDP. Here, we further improved the coating procedure to enhance the ease and repeatability of the cationic coating preparation by employing 2,2'-azobisisobutyronitrile (AIBN) as the radical initiator and methanol as the solvent. The new coating method not only simplifies the coating process but is also user-friendly. Different laboratory members were able to reproduce this type of cationic coating with consistent CZE-MS performance. We evaluated the performance of CZE-MS with the cationic coating in analyzing various complex biological samples (nanoparticle protein corona, histone, and an Escherichia coli cell lysate) and assessed its long-term reproducibility with an E. coli cell lysate for 35 runs (over 40 h) of continuous measurement. The CZE-MS system produced reproducible measurements for all the samples regarding separation profiles, proteoform migration time (MT), and proteoform intensity. For example, the system enabled the detection of large proteoforms (26-35 kDa) from an E. coli sample with consistent MT, relative standard deviations (RSDs) <7% without MT correction and 2.1% after MT alignment. We expect that the APTAC coating will further advance CZE-MS-based TDP for broad and large-scale applications.

Journal of Mass SpectrometryVol. 61(1)
Michigan State University (US)
National Science Foundation, National Cancer Institute, National Institute of General Medical Sciences
Openalex Percentile: Top 22%
Mass Spectrometry Techniques and Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.