Evaluation of sensitivity and scatter fraction in gamma camera using a thallium bromide semiconductor detector: a monte carlo study

Abstract Thallium bromide (TlBr), as a scintillation material, is widely used for gamma-ray detection. His high detection efficiency is attributed to his high atomic number and effective attenuation coefficient. This investigation aimed to compare the image quality of TlBr with traditional detectors, including cadmium zinc telluride (CZT) and cadmium telluride (CdTe), in gamma camera scintigraphy. The comparison was conducted with respect to variations in parallel-hole collimator geometry. This work was carried out using the Geant4 Application for Tomographic Emission (GATE) simulation toolkit. TlBr, CdTe, and CZT semiconductor materials were employed, and collimator lengths were modeled as 0.4 to 1.0 cm in 0.2 cm increments. Qualitative analysis was performed using images acquired from a quadrant-bar phantom featuring bars of multiple thicknesses. Scatter fraction and sensitivity (cps/MBq) were quantitatively evaluated using a 37 Mbq point source of 99m Tc . At 0.4, 0.6, 0.8, and 1.0 cm of collimator lengths, respectively, TlBr’s sensitivities were 2.46, 2.56, 2.72, and 2.88 times higher than those of CZT and CdTe. The scatter fraction for TlBr, CdTe, and CZT detectors was 1.41, 1.36, and 1.38 times lower at 1.0 cm collimator length than at 0.4 cm. CdTe and CZT materials exhibited no notable differences in either sensitivity or scatter fraction. These results confirm that TlBr is a promising alternative detector material for gamma camera scintigraphy. It provides enhanced sensitivity and a lower scatter fraction.

Authors

Institutions

Publication Details

Journal
The European Physical Journal Plus
Published
2025-12-27
DOI
https://doi.org/10.1140/epjp/s13360-025-07108-z
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of sensitivity and scatter fraction in gamma camera using a thallium bromide semiconductor detector: a monte carlo study

M. A. Ghoneim
The European Physical Journal Plus
Medical Imaging Techniques and Applications
article

Evaluation of sensitivity and scatter fraction in gamma camera using a thallium bromide semiconductor detector: a monte carlo study

M. A. Ghoneim
article en

Abstract

Abstract Thallium bromide (TlBr), as a scintillation material, is widely used for gamma-ray detection. His high detection efficiency is attributed to his high atomic number and effective attenuation coefficient. This investigation aimed to compare the image quality of TlBr with traditional detectors, including cadmium zinc telluride (CZT) and cadmium telluride (CdTe), in gamma camera scintigraphy. The comparison was conducted with respect to variations in parallel-hole collimator geometry. This work was carried out using the Geant4 Application for Tomographic Emission (GATE) simulation toolkit. TlBr, CdTe, and CZT semiconductor materials were employed, and collimator lengths were modeled as 0.4 to 1.0 cm in 0.2 cm increments. Qualitative analysis was performed using images acquired from a quadrant-bar phantom featuring bars of multiple thicknesses. Scatter fraction and sensitivity (cps/MBq) were quantitatively evaluated using a 37 Mbq point source of 99m Tc . At 0.4, 0.6, 0.8, and 1.0 cm of collimator lengths, respectively, TlBr’s sensitivities were 2.46, 2.56, 2.72, and 2.88 times higher than those of CZT and CdTe. The scatter fraction for TlBr, CdTe, and CZT detectors was 1.41, 1.36, and 1.38 times lower at 1.0 cm collimator length than at 0.4 cm. CdTe and CZT materials exhibited no notable differences in either sensitivity or scatter fraction. These results confirm that TlBr is a promising alternative detector material for gamma camera scintigraphy. It provides enhanced sensitivity and a lower scatter fraction.

The European Physical Journal PlusVol. 140(12)
South Valley University (EG)
Science and Technology Development Fund
Openalex Percentile: Top 30%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.