Application of Noise2Inverse and adaptation (Noise2Phase) to single‐mask x‐ray phase contrast micro‐computed tomography

X-ray phase contrast imaging (XPCI), when implemented in micro-computed tomography (micro-CT) mode, offers high-contrast 3D imaging of weakly-attenuating material samples. In the so-called single-mask edge illumination approach, a mask with periodically spaced transmitting apertures is used to split the x-ray beam into narrow beamlets; when the beamlets are aligned with the boundaries ('edges') between detector pixels, their refraction-induced deviation can be detected and used to form images. A shortcoming is that the mask reduces the x-ray flux, necessitating longer exposures and therefore longer acquisition times. We show that the demand on exposure time can be relaxed by integrating the deep learning-based denoising technique Noise2Inverse into the image processing workflow. The applicability of Noise2Inverse to single-mask edge illumination XPCI micro-CT is demonstrated, and its performance at severe noise levels is explored. Taking advantage of the distinct imaging system characteristics, we also propose an adaptation of Noise2Inverse, called Noise2Phase, which does not rely on splitting the CT dataset by projections.

Authors

Institutions

Publication Details

Journal
Journal of Microscopy
Published
2025-12-27
DOI
https://doi.org/10.1111/jmi.70056
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Noise2Inverse and adaptation (Noise2Phase) to single‐mask x‐ray phase contrast micro‐computed tomography

Charlotte K. Hagen, Alberto Astolfo, Alexander Denker, G. Lioliou et al.
Journal of Microscopy
Advanced X-ray Imaging Techniques
article

Application of Noise2Inverse and adaptation (Noise2Phase) to single‐mask x‐ray phase contrast micro‐computed tomography

Charlotte K. Hagen, Alberto Astolfo, Alexander Denker, G. Lioliou, D. Chen, Marco Endrizzi, Alessandro Olivo, Khushal Shah, Peter Munro
article en

Abstract

X-ray phase contrast imaging (XPCI), when implemented in micro-computed tomography (micro-CT) mode, offers high-contrast 3D imaging of weakly-attenuating material samples. In the so-called single-mask edge illumination approach, a mask with periodically spaced transmitting apertures is used to split the x-ray beam into narrow beamlets; when the beamlets are aligned with the boundaries ('edges') between detector pixels, their refraction-induced deviation can be detected and used to form images. A shortcoming is that the mask reduces the x-ray flux, necessitating longer exposures and therefore longer acquisition times. We show that the demand on exposure time can be relaxed by integrating the deep learning-based denoising technique Noise2Inverse into the image processing workflow. The applicability of Noise2Inverse to single-mask edge illumination XPCI micro-CT is demonstrated, and its performance at severe noise levels is explored. Taking advantage of the distinct imaging system characteristics, we also propose an adaptation of Noise2Inverse, called Noise2Phase, which does not rely on splitting the CT dataset by projections.

Journal of Microscopy
University College London (GB)
Openalex Percentile: Top 26%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application of Noise2Inverse and adaptation (Noise2Phase) to single‐mask x‐ray phase contrast micro‐computed tomography — Charlotte K. Hagen, Alberto Astolfo, et al. · Journal of Microscopy (2025) | TGRS Research Map | TGRS