In-situ evaluation of a fuel-switching heating system in Edmonton, Alberta, Canada: Lessons learned

In the residential sector, energy consumption and greenhouse gas (GHG) emissions remain key issues. Heat pumps are an emerging technology that shows promise of addressing both these issues through the electrification of space heating. Cold climates pose a unique challenge to specifically air-source heat pumps (ASHPs) due to reduced efficiency at lower ambient temperatures. A solution to this is fuel-switching heating systems, which can potentially reduce utility costs, GHG emissions, or energy consumption through the optimized utilization of multiple fuel sources for space heating. This study aims to investigate the energy efficiency and GHG emissions of a fuel-switching heating system composed of an ASHP and tankless water heater (TWH) in the city of Edmonton, Alberta, which is characterized by a cold climate. The key lessons learned from this in-situ evaluation were (1) The studied units consumed 13,361 kWh (52.7%) less total energy and emitted 3364 kgCO 2 eq (62.8%) fewer GHG emissions compared to the average rowhouse in Alberta. Despite exhibiting promising reductions, caution is required before implementing increased electrification measures in regions with high-pollution generation methods, such as Alberta. (2) The efficiency of fuel-switching systems is dependent on the controller. It was found that half of the studied units never utilized their ASHP for space heating, and that these units consumed 14.5% less HVAC energy compared to units with regular ASHP heating. This was caused by poor controller configuration, where the ASHP and TWH were operated on a single control loop, leading to the ASHPs being utilized in extreme cold conditions, and (3) Occupant behavior has a significant impact on energy performance between units. When investigating an occupant change for a single unit, the new occupants were found to consume up to 2.07 times more plug energy and 1.50 times HVAC and DHW energy during periods with similar weather conditions.

Authors

Institutions

Publication Details

Journal
Journal of Building Physics
Published
2025-12-26
DOI
https://doi.org/10.1177/17442591251403223
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-situ evaluation of a fuel-switching heating system in Edmonton, Alberta, Canada: Lessons learned

Alexander Jordan, Bowen Yang, Yuxiang Chen
Journal of Building Physics
Geothermal Energy Systems and Applications
article

In-situ evaluation of a fuel-switching heating system in Edmonton, Alberta, Canada: Lessons learned

Alexander Jordan, Bowen Yang, Yuxiang Chen
article en

Abstract

In the residential sector, energy consumption and greenhouse gas (GHG) emissions remain key issues. Heat pumps are an emerging technology that shows promise of addressing both these issues through the electrification of space heating. Cold climates pose a unique challenge to specifically air-source heat pumps (ASHPs) due to reduced efficiency at lower ambient temperatures. A solution to this is fuel-switching heating systems, which can potentially reduce utility costs, GHG emissions, or energy consumption through the optimized utilization of multiple fuel sources for space heating. This study aims to investigate the energy efficiency and GHG emissions of a fuel-switching heating system composed of an ASHP and tankless water heater (TWH) in the city of Edmonton, Alberta, which is characterized by a cold climate. The key lessons learned from this in-situ evaluation were (1) The studied units consumed 13,361 kWh (52.7%) less total energy and emitted 3364 kgCO 2 eq (62.8%) fewer GHG emissions compared to the average rowhouse in Alberta. Despite exhibiting promising reductions, caution is required before implementing increased electrification measures in regions with high-pollution generation methods, such as Alberta. (2) The efficiency of fuel-switching systems is dependent on the controller. It was found that half of the studied units never utilized their ASHP for space heating, and that these units consumed 14.5% less HVAC energy compared to units with regular ASHP heating. This was caused by poor controller configuration, where the ASHP and TWH were operated on a single control loop, leading to the ASHPs being utilized in extreme cold conditions, and (3) Occupant behavior has a significant impact on energy performance between units. When investigating an occupant change for a single unit, the new occupants were found to consume up to 2.07 times more plug energy and 1.50 times HVAC and DHW energy during periods with similar weather conditions.

Journal of Building Physics
University of Alberta (CA)
Affordable and clean energy
Openalex Percentile: Top 52%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.