Anion Exchange and Nebulizer-Enhanced Online UV-Chemiluminescence Analyzer Coupled with LC-MS for Total and Novel N-Nitrosamines in Cigarettes and e-Juices

Quantification of total N-nitrosamines (TONO) is critical for assessing environmental carcinogens. UV-chemiluminescence (UV-CL) shows promise for TONO analysis; however, the data accuracy is limited by matrix interference and the analyte-specific method sensitivity. To overcome these challenges, we designed a new online UV-CL analyzer integrating anion exchange cartridges (AEC) and a homemade nebulizer. The AEC eliminates interference from a wide concentration range of NO<sub>2</sub><sup>-</sup>. The nebulizer effectively introduces both volatile and less-volatile nitrosamines, achieving 98.4% photolysis while requiring only 14-53% of the UV dosage used in previous studies. Our analyzer achieved a universal calibration across structurally diverse N-nitrosamines, simplifying quantitative N-nitrosamine measurements. We further demonstrated its application by measuring TONO in authentic tobacco products. Compared to liquid chromatography mass spectrometry (LC-MS), the analyzer obtained consistent kinetic results when monitoring the reaction between NO<sub>2</sub><sup>-</sup> and nornicotine, supporting its application in kinetic studies. Moreover, our preliminary analysis of flavored e-juices shows that they could contain up to 0.24 μmol/g of TONO, which could increase further when an environmental level of NO<sub>2</sub><sup>-</sup> (6.7 mg/L) is present. Comparing results obtained using the analyzer and LC-MS, known tobacco-specific nitrosamines (TSNAs) account for less than 5.5% of TONO, indicating that most N-nitrosamines in tobacco are unknown. This led to the tentative identification of two new N-nitrosamines: pyridine-methylated N-nitrosoanatabine and pyridine-methylated N-nitrosoanabasine using high-resolution HPLC-MS/MS. Our results supported the feasibility of using the UV-CL analyzer for rapid TONO measurements and highlighted the need to monitor N-nitrosamine contamination in e-juice and tobacco products.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-12-27
DOI
https://doi.org/10.1021/acs.analchem.5c05034
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anion Exchange and Nebulizer-Enhanced Online UV-Chemiluminescence Analyzer Coupled with LC-MS for Total and Novel N-Nitrosamines in Cigarettes and e-Juices

Qiming Shen, Ran Zhao, Bryce N. Thomas, Di Zhang et al.
Analytical Chemistry
Water Treatment and Disinfection
article

Anion Exchange and Nebulizer-Enhanced Online UV-Chemiluminescence Analyzer Coupled with LC-MS for Total and Novel N-Nitrosamines in Cigarettes and e-Juices

Qiming Shen, Ran Zhao, Bryce N. Thomas, Di Zhang, X. Andrew Guo, Shakiba Talebian, K. N. Minh Chau, Anastasiia Kim, Xing-Fang Li
article en

Abstract

Quantification of total N-nitrosamines (TONO) is critical for assessing environmental carcinogens. UV-chemiluminescence (UV-CL) shows promise for TONO analysis; however, the data accuracy is limited by matrix interference and the analyte-specific method sensitivity. To overcome these challenges, we designed a new online UV-CL analyzer integrating anion exchange cartridges (AEC) and a homemade nebulizer. The AEC eliminates interference from a wide concentration range of NO<sub>2</sub><sup>-</sup>. The nebulizer effectively introduces both volatile and less-volatile nitrosamines, achieving 98.4% photolysis while requiring only 14-53% of the UV dosage used in previous studies. Our analyzer achieved a universal calibration across structurally diverse N-nitrosamines, simplifying quantitative N-nitrosamine measurements. We further demonstrated its application by measuring TONO in authentic tobacco products. Compared to liquid chromatography mass spectrometry (LC-MS), the analyzer obtained consistent kinetic results when monitoring the reaction between NO<sub>2</sub><sup>-</sup> and nornicotine, supporting its application in kinetic studies. Moreover, our preliminary analysis of flavored e-juices shows that they could contain up to 0.24 μmol/g of TONO, which could increase further when an environmental level of NO<sub>2</sub><sup>-</sup> (6.7 mg/L) is present. Comparing results obtained using the analyzer and LC-MS, known tobacco-specific nitrosamines (TSNAs) account for less than 5.5% of TONO, indicating that most N-nitrosamines in tobacco are unknown. This led to the tentative identification of two new N-nitrosamines: pyridine-methylated N-nitrosoanatabine and pyridine-methylated N-nitrosoanabasine using high-resolution HPLC-MS/MS. Our results supported the feasibility of using the UV-CL analyzer for rapid TONO measurements and highlighted the need to monitor N-nitrosamine contamination in e-juice and tobacco products.

Analytical ChemistryVol. 98(1)
University of Alberta (CA), Society of Environmental Toxicology and Chemistry (US)
Good health and well-being
Openalex Percentile: Top 33%
Water Treatment and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.