Factors Influencing the Use of Patient-Specific Instrumentation (PSI) in Shoulder Arthroplasty: A Single-Centre Study

Background Accurate component placement is vital for shoulder arthroplasty success, with poor positioning linked to a range of clinical complications. This study aims to identify which patient, anatomical and surgical factors influenced the adoption of patient-specific instrumentation (PSI) for glenoid component placement. These included patient demographics, implant type, glenoid version and inclination, glenoid dimensions, use of augmentation, and surgeon-related factors. Methodology A retrospective decision-analysis study of 191 shoulder arthroplasty cases (reverse and anatomical) conducted between 2021 and 2024 at a single NHS trust. Preoperative imaging protocols, component planning, degree of deformity and intraoperative decision-making were examined. The primary outcome was the association between anatomical factors and PSI use. Statistical analysis performed using SPSS v16 (SPSS Inc., Chicago, IL). Results PSI use was strongly associated with increased glenoid retroversion (Cramér's V = 0.37, <i>P</i> < 0.001) and superior inclination (Cramér's V = 0.30, <i>P</i> = 0.001), and moderately associated with the use of medium and large glenoid augments (Cramér's V = 0.33, <i>P</i> < 0.001). No significant association was observed between PSI use and patient age, sex, surgical side, glenoid anteroposterior width, or vault depth (all Cramér's V < 0.15). Conclusions PSI is primarily adopted in cases with complex glenoid deformities. This study analyses decision-making patterns rather than clinical effectiveness. This may help inform future work towards more consistent PSI selection.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-12-27
DOI
https://doi.org/10.7759/cureus.100208
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors Influencing the Use of Patient-Specific Instrumentation (PSI) in Shoulder Arthroplasty: A Single-Centre Study

Srikiran Thalanki, Adam Daneshyar, Tim McBride, Omar Mostafa et al.
Cureus
Shoulder Injury and Treatment
article

Factors Influencing the Use of Patient-Specific Instrumentation (PSI) in Shoulder Arthroplasty: A Single-Centre Study

Srikiran Thalanki, Adam Daneshyar, Tim McBride, Omar Mostafa, Alan M. Simons, Anurag Dixit
article en

Abstract

Background Accurate component placement is vital for shoulder arthroplasty success, with poor positioning linked to a range of clinical complications. This study aims to identify which patient, anatomical and surgical factors influenced the adoption of patient-specific instrumentation (PSI) for glenoid component placement. These included patient demographics, implant type, glenoid version and inclination, glenoid dimensions, use of augmentation, and surgeon-related factors. Methodology A retrospective decision-analysis study of 191 shoulder arthroplasty cases (reverse and anatomical) conducted between 2021 and 2024 at a single NHS trust. Preoperative imaging protocols, component planning, degree of deformity and intraoperative decision-making were examined. The primary outcome was the association between anatomical factors and PSI use. Statistical analysis performed using SPSS v16 (SPSS Inc., Chicago, IL). Results PSI use was strongly associated with increased glenoid retroversion (Cramér's V = 0.37, <i>P</i> < 0.001) and superior inclination (Cramér's V = 0.30, <i>P</i> = 0.001), and moderately associated with the use of medium and large glenoid augments (Cramér's V = 0.33, <i>P</i> < 0.001). No significant association was observed between PSI use and patient age, sex, surgical side, glenoid anteroposterior width, or vault depth (all Cramér's V < 0.15). Conclusions PSI is primarily adopted in cases with complex glenoid deformities. This study analyses decision-making patterns rather than clinical effectiveness. This may help inform future work towards more consistent PSI selection.

CureusVol. 17(12)
Cardiff and Vale University Health Board (GB), Russells Hall Hospital (GB), Royal Orthopaedic Hospital (GB), The Royal Wolverhampton NHS Trust (GB)
Openalex Percentile: Top 26%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Factors Influencing the Use of Patient-Specific Instrumentation (PSI) in Shoulder Arthroplasty: A Single-Centre Study — Srikiran Thalanki, Adam Daneshyar, et al. · Cureus (2025) | TGRS Research Map | TGRS