Thermally Activated Delayed Mechano‐ and Radioluminescence Enabling Long‐Term and Time‐Delayed Spatiotemporal Stress and X‐ray Imaging

ABSTRACT Current stress visualization techniques face limitations due to the transient signal capture of traditional mechanoluminescent (ML) materials, restricting the retrieval of historical mechanical data and hindering long‐term damage diagnosis for high‐end equipment. This study overcomes these constraints by precisely regulating trap energy levels in β ‐Ca 3 (PO 4 ) 2 : Dy through gradient Li + doping, resulting in significantly enhanced thermally delayed luminescence performance under mechanical or X‐ray excitation. Lattice distortion and charge compensation from Li + aggregation increase trap density, extending spatiotemporal imaging signal traceability beyond 45 days. Notably, the triboelectric effect at the organic–inorganic interface triggered by mechanical stimulation not only induces transient ML but also facilitates the capture of charge carriers at intrinsic defect states of phosphors. Inspired by static high‐energy X‐ray imaging based on trap filling, by employing passive mechanical responses for trap filling and thermal activation for delayed carrier release, dynamic stress distribution is visually monitored, overcoming conventional ML's rapid signal decay. Experimental and theoretical results confirm that high‐energy stimulation ionizes oxygen vacancies into paramagnetic states, enabling electron capture and thermally activated release. The proposed self‐capture and thermal‐delay response technology offers an innovative strategy for precise damage localization in high‐speed collisions, creating a new pathway for static/dynamic defect tracking in advanced equipment.

Authors

Institutions

Publication Details

Journal
Advanced Functional Materials
Published
2025-12-27
DOI
https://doi.org/10.1002/adfm.202527248
Citations
1
Primary Topic
Luminescence Properties of Advanced Materials
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermally Activated Delayed Mechano‐ and Radioluminescence Enabling Long‐Term and Time‐Delayed Spatiotemporal Stress and X‐ray Imaging

Meiguang Zhang, Haojin Liu, Yunmei Song, Weizhi Tian et al.
1 citations
Advanced Functional Materials
Luminescence Properties of Advanced Materials
0.52
article

Thermally Activated Delayed Mechano‐ and Radioluminescence Enabling Long‐Term and Time‐Delayed Spatiotemporal Stress and X‐ray Imaging

Meiguang Zhang, Haojin Liu, Yunmei Song, Weizhi Tian, Ziyi Guo, Lei Zhao, Yuanting Wu, Ou Hai, Pengfei Zhang, Xingliang Luo
article en
1 citations

Abstract

ABSTRACT Current stress visualization techniques face limitations due to the transient signal capture of traditional mechanoluminescent (ML) materials, restricting the retrieval of historical mechanical data and hindering long‐term damage diagnosis for high‐end equipment. This study overcomes these constraints by precisely regulating trap energy levels in β ‐Ca 3 (PO 4 ) 2 : Dy through gradient Li + doping, resulting in significantly enhanced thermally delayed luminescence performance under mechanical or X‐ray excitation. Lattice distortion and charge compensation from Li + aggregation increase trap density, extending spatiotemporal imaging signal traceability beyond 45 days. Notably, the triboelectric effect at the organic–inorganic interface triggered by mechanical stimulation not only induces transient ML but also facilitates the capture of charge carriers at intrinsic defect states of phosphors. Inspired by static high‐energy X‐ray imaging based on trap filling, by employing passive mechanical responses for trap filling and thermal activation for delayed carrier release, dynamic stress distribution is visually monitored, overcoming conventional ML's rapid signal decay. Experimental and theoretical results confirm that high‐energy stimulation ionizes oxygen vacancies into paramagnetic states, enabling electron capture and thermally activated release. The proposed self‐capture and thermal‐delay response technology offers an innovative strategy for precise damage localization in high‐speed collisions, creating a new pathway for static/dynamic defect tracking in advanced equipment.

Advanced Functional Materials
Shaanxi University of Technology (CN), Baoji University of Arts and Sciences (CN), Shaanxi University of Science and Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Shaanxi Province
Affordable and clean energy
Openalex Percentile: Top 29%
Luminescence Properties of Advanced Materials
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.