ATR-FTIR Spectroscopy for Detection of Anti-interferon-Gamma Autoantibodies

<b>Introduction:</b> Adult-onset immunodeficiency (AOID) unrelated to HIV is commonly linked to anti-interferon-gamma autoantibodies (AIGAs), predisposing patients to life-threatening opportunistic infections. Current AIGA detection methods are time-consuming and resource intensive. This study aimed to develop and validate an attenuated total reflectance-Fourier transform infrared (ATR-FTIR) technique for detecting and differentiating AIGA-positive patients. <b>Methods:</b> We recruited individuals into three groups: AIGA-positive patients (<i>n</i> = 45), AIGA-negative patients (<i>n</i> = 15), and healthy controls (<i>n</i> = 15). Heparinized plasma or serum samples underwent ATR-FTIR spectroscopy. Spectral profiles were examined using principal component analysis (PCA) and partial least-squares-discriminant analysis (PLS-DA). The reference standard for AIGA concentration was determined by the inhibitory enzyme-linked immunosorbent assay (ELISA). <b>Results:</b> ATR-FTIR spectra revealed significant differences, especially in the amide and fingerprint regions, particularly at key wavenumbers 1632 cm<sup>-1</sup> and 1535 cm<sup>-1</sup>. The Amide I/Amide I + II + III ratio is significant between AIGA-positive and others and a secondary structure protein conformational change α-helix to β-sheet. PCA and PLS-DA enabled effective separation of patient groups; PLS-DA and k-NN achieved 95% accuracy, 93.3% sensitivity, and 100% specificity for differentiating AIGA-positive from negative/healthy individuals (NPV 83.3%; PPV 100%). The amide region (1700-1500 cm<sup>‑1</sup>) delivered the best prediction accuracy. <b>Conclusion:</b> ATR-FTIR spectroscopy demonstrates significant potential as a rapid and effective diagnostic tool for differentiating AIGA-positive patients from healthy individuals, providing a valuable addition to clinical diagnostic practices. Further validation in larger, diverse populations is warranted.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-12-26
DOI
https://doi.org/10.1021/acsomega.5c11499
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ATR-FTIR Spectroscopy for Detection of Anti-interferon-Gamma Autoantibodies

Sonwit Phanabamrung, Molin Wongwattanakul, Ploenchan Chetchotisakd, G. Lertmemongkolchai et al.
ACS Omega
Advanced Biosensing Techniques and Applications
article

ATR-FTIR Spectroscopy for Detection of Anti-interferon-Gamma Autoantibodies

Sonwit Phanabamrung, Molin Wongwattanakul, Ploenchan Chetchotisakd, G. Lertmemongkolchai, Siriluck Anunnatsiri, Patutong Chatchawal, Pattaraporn Srisai, Chanchai Hongsa, Varis Manbenmad, Arnone Nithichanon
article en

Abstract

<b>Introduction:</b> Adult-onset immunodeficiency (AOID) unrelated to HIV is commonly linked to anti-interferon-gamma autoantibodies (AIGAs), predisposing patients to life-threatening opportunistic infections. Current AIGA detection methods are time-consuming and resource intensive. This study aimed to develop and validate an attenuated total reflectance-Fourier transform infrared (ATR-FTIR) technique for detecting and differentiating AIGA-positive patients. <b>Methods:</b> We recruited individuals into three groups: AIGA-positive patients (<i>n</i> = 45), AIGA-negative patients (<i>n</i> = 15), and healthy controls (<i>n</i> = 15). Heparinized plasma or serum samples underwent ATR-FTIR spectroscopy. Spectral profiles were examined using principal component analysis (PCA) and partial least-squares-discriminant analysis (PLS-DA). The reference standard for AIGA concentration was determined by the inhibitory enzyme-linked immunosorbent assay (ELISA). <b>Results:</b> ATR-FTIR spectra revealed significant differences, especially in the amide and fingerprint regions, particularly at key wavenumbers 1632 cm<sup>-1</sup> and 1535 cm<sup>-1</sup>. The Amide I/Amide I + II + III ratio is significant between AIGA-positive and others and a secondary structure protein conformational change α-helix to β-sheet. PCA and PLS-DA enabled effective separation of patient groups; PLS-DA and k-NN achieved 95% accuracy, 93.3% sensitivity, and 100% specificity for differentiating AIGA-positive from negative/healthy individuals (NPV 83.3%; PPV 100%). The amide region (1700-1500 cm<sup>‑1</sup>) delivered the best prediction accuracy. <b>Conclusion:</b> ATR-FTIR spectroscopy demonstrates significant potential as a rapid and effective diagnostic tool for differentiating AIGA-positive patients from healthy individuals, providing a valuable addition to clinical diagnostic practices. Further validation in larger, diverse populations is warranted.

ACS OmegaVol. 11(1)
Khon Kaen University (TH), Center for Innovation (US), Chiang Mai University (TH)
Reduced inequalities
Openalex Percentile: Top 36%
Advanced Biosensing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.