Analysis of the abnormal wear of the pantograph contact strip through combined experimental and simulation approaches

The carbon contact strip of pantograph collects current from the overhead catenary to power the train, inevitably causing wear to the contact surface. This paper addresses the abnormal wear of the pantograph carbon contact strip, a challenged accident encountered in operation and maintenance. This issue involves aspects of tribology, dynamics interaction, and electrical contact, making it difficult to explain from a single perspective. Therefore, a comprehensive analysis was conducted using field testing, laboratory experiments, and simulation, focusing on frequency matching, dynamic interaction, and wear performance. The results revealed that during operation, a frequency mismatch between the pantograph and the catenary led to the activation of the problem during dynamic interactions. This instability resulted in a reduced contact area, increased contact stress, and a sharp rise in current density, all of which contributed to higher wear rates and abnormal profiles of the contact surface. Furthermore, these changes, along with the reduced environmental humidity, further deteriorated the wear and dynamic performance of the system. Subsequent structural and parameter adjustments can optimize this issue.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-27
DOI
https://doi.org/10.1038/s41598-025-28380-0
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the abnormal wear of the pantograph contact strip through combined experimental and simulation approaches

Haifei Wei, Hongming Chen, Weihua Zhang, Xingshuai Zhi et al.
Scientific Reports
Electrical Contact Performance and Analysis
article

Analysis of the abnormal wear of the pantograph contact strip through combined experimental and simulation approaches

Haifei Wei, Hongming Chen, Weihua Zhang, Xingshuai Zhi, Yi Sun, Guanhua Huang, Langtao Zhao, Ning Zhou, Yao Cheng
article en

Abstract

The carbon contact strip of pantograph collects current from the overhead catenary to power the train, inevitably causing wear to the contact surface. This paper addresses the abnormal wear of the pantograph carbon contact strip, a challenged accident encountered in operation and maintenance. This issue involves aspects of tribology, dynamics interaction, and electrical contact, making it difficult to explain from a single perspective. Therefore, a comprehensive analysis was conducted using field testing, laboratory experiments, and simulation, focusing on frequency matching, dynamic interaction, and wear performance. The results revealed that during operation, a frequency mismatch between the pantograph and the catenary led to the activation of the problem during dynamic interactions. This instability resulted in a reduced contact area, increased contact stress, and a sharp rise in current density, all of which contributed to higher wear rates and abnormal profiles of the contact surface. Furthermore, these changes, along with the reduced environmental humidity, further deteriorated the wear and dynamic performance of the system. Subsequent structural and parameter adjustments can optimize this issue.

Scientific ReportsVol. 15(1)
Chengdu Institute of Information Technology (China) (CN), Southwest Jiaotong University (CN)
Openalex Percentile: Top 44%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.