Uncovering hidden protein conformations with high bandwidth nanopore measurements.

Advanced nanopore measurements allow structural probing of molecules with high spatial and temporal resolution. We report high signal-to-noise, 1-10 MHz bandwidth, translocation measurements of the multi-state folding of heme protein cytochrome c in KCl solution through optimally designed silicon nitride pores of 2.3-3.3 nm diameter and 3.6-3.8 nm effective thickness, and an optimal concentration of a denaturant (Gdm-Cl). The pore diameter is slightly smaller than the protein size, forcing the protein to squeeze through the pore. The sufficiently large pore thickness allows enough time for protein probing at an applied field of approximately 250 kV/cm. Through Bayesian Information Criterion score analysis, current blockades reveal six distinct levels, attributed to specific protein states. We calculate the transition probabilities between the states and the conditional probabilities of the protein leaving the pore from each state. We validate the model by simulating events and comparing them to experimental data.

Authors

Publication Details

Journal
PubMed
Published
2025-12-17
Primary Topic
Nanopore and Nanochannel Transport Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncovering hidden protein conformations with high bandwidth nanopore measurements.

Kyril Kavetsky, Marija Drndić, Sabine Hong, Roger Yang et al.
PubMed
Nanopore and Nanochannel Transport Studies
article

Uncovering hidden protein conformations with high bandwidth nanopore measurements.

Kyril Kavetsky, Marija Drndić, Sabine Hong, Roger Yang, Chih-Yuan Lin
article en

Abstract

Advanced nanopore measurements allow structural probing of molecules with high spatial and temporal resolution. We report high signal-to-noise, 1-10 MHz bandwidth, translocation measurements of the multi-state folding of heme protein cytochrome c in KCl solution through optimally designed silicon nitride pores of 2.3-3.3 nm diameter and 3.6-3.8 nm effective thickness, and an optimal concentration of a denaturant (Gdm-Cl). The pore diameter is slightly smaller than the protein size, forcing the protein to squeeze through the pore. The sufficiently large pore thickness allows enough time for protein probing at an applied field of approximately 250 kV/cm. Through Bayesian Information Criterion score analysis, current blockades reveal six distinct levels, attributed to specific protein states. We calculate the transition probabilities between the states and the conditional probabilities of the protein leaving the pore from each state. We validate the model by simulating events and comparing them to experimental data.

PubMed
Openalex Percentile: Top 42%
Nanopore and Nanochannel Transport Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Uncovering hidden protein conformations with high bandwidth nanopore measurements. — Kyril Kavetsky, Marija Drndić, et al. · PubMed (2025) | TGRS Research Map | TGRS