High-resolution Dante spectrometer based on quasi-monochromatic multilayer mirror array for soft X-ray spectral measurement in plasma diagnostics

Soft X-ray spectroscopic diagnostics based on Dante spectrometers are essential for evaluating plasma conditions driven by Z-pinch or laser fusion. A Dante spectrometer configuration capable of achieving low spectral measurement uncertainty remains a bottleneck problem at present. This paper develops a quantitative uncertainty-analysis framework for Dante spectrometers employing an array of quasi-monochromatic multilayer mirrors. Accordingly, we further developed a set of practical methods, including the precise synchrotron radiation calibration and optimized spectrometer installation, to effectively suppress these measurement uncertainties. For implementation, we developed a Dante spectrometer covering 100-1000 eV and validated it on a Z-pinch platform. The relative expanded uncertainty of individual channels was maintained within 2%-3%, and the reconstructed spectral-distribution uncertainty was better than 3.2%.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-12-26
DOI
https://doi.org/10.1364/oe.581941
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-resolution Dante spectrometer based on quasi-monochromatic multilayer mirror array for soft X-ray spectral measurement in plasma diagnostics

Yongtang Liu, Du Huiyao, Haoxuan Si, Bo Tang et al.
Optics Express
Laser-Plasma Interactions and Diagnostics
article

High-resolution Dante spectrometer based on quasi-monochromatic multilayer mirror array for soft X-ray spectral measurement in plasma diagnostics

Yongtang Liu, Du Huiyao, Haoxuan Si, Bo Tang, Ermeng Zhang, Hao Xu, Zhe Zhang, Ke Dong, Zhanshan Wang, Jun Chen, Shengzhen Yi
article en

Abstract

Soft X-ray spectroscopic diagnostics based on Dante spectrometers are essential for evaluating plasma conditions driven by Z-pinch or laser fusion. A Dante spectrometer configuration capable of achieving low spectral measurement uncertainty remains a bottleneck problem at present. This paper develops a quantitative uncertainty-analysis framework for Dante spectrometers employing an array of quasi-monochromatic multilayer mirrors. Accordingly, we further developed a set of practical methods, including the precise synchrotron radiation calibration and optimized spectrometer installation, to effectively suppress these measurement uncertainties. For implementation, we developed a Dante spectrometer covering 100-1000 eV and validated it on a Z-pinch platform. The relative expanded uncertainty of individual channels was maintained within 2%-3%, and the reconstructed spectral-distribution uncertainty was better than 3.2%.

Optics ExpressVol. 34(2)
Northwest Institute of Nuclear Technology (CN)
Openalex Percentile: Top 21%
Laser-Plasma Interactions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-resolution Dante spectrometer based on quasi-monochromatic multilayer mirror array for soft X-ray spectral measurement in plasma diagnostics — Yongtang Liu, Du Huiyao, et al. · Optics Express (2025) | TGRS Research Map | TGRS